Safety Notes 

Read these safety notes carefully before using this product to ensure that you 
operate the equipment safely. 

Your GERA product and recommended supplies have been designed and tested 
to meet strict safety requirements.  These include safety agency approval, and 
compliance with established environmental standards.  Please read the following 
instructions carefully before operating the product and refer to them as needed to 
ensure the continued safe operation of your product.  

The safety and environment testing and performance of this product have been 
verified using GERA materials only.  

 

WARNING: Any unauthorized alteration, which may include the addition 

of new functions or connection of external devices, may affect 
the product certification.  Please contact your Authorized 
Local Dealer for more information. 

 

Warning Markings 

All warning instructions marked on or supplied with the product should be 
followed. 

 

WARNING

 

This WARNING alerts users to areas of the 
product where there is the possibility of 
personal injury 

!

 

CAUTION

 

This CAUTION alerts user that a wrong 
operation could damage the Folder 

 

NOTE 

This NOTE symbol alerts user to pay 
attention  in the operation described 

 

Electrical Supply 

This product shall be operated from the type of electrical supply indicated on 
the product's data plate label.   

If you are not sure that your electrical supply meets the requirements, please 
consult your local power company for advice. 

WARNING:  

This product must be connected to a protective grounded circuit.

 

This product is supplied with a plug that has a protective grounding pin. This 
plug will only fit into a grounded electrical outlet.  This is a safety feature.  To 
avoid risk of electric shock, contact your electrician to replace the electrical 
outlet if you are unable to insert the plug into it. Never use a grounding adapter 
plug to connect the product to an electrical outlet that lacks a grounded 
connection terminal. 

 

 

Operator Accessible Areas 

This equipment has been designed to restrict operator access to safe areas only.  
Operator access to hazardous areas is restricted with covers or guards, which 
would require a tool to remove.  Never remove these covers or guards.  

WARNING – Electrical Safety Information 

• 

Use only the power cord supplied with this equipment. 

• 

Plug the power cord directly into a grounded electrical outlet.  Do not use an 
extension cord.  If you do not know if an outlet is grounded, consult a 
qualified electrician. 

If this machine needs to be moved to a different location, contact a GERA 
service representative or your authorized local representative or service support 
organization. 

• 

Improper connection of the equipment-grounding conductor can result in 
electrical shock. 

• 

Do not place this equipment where people might step or trip on the power 
cord. 

• 

Do not place objects on the power cord. 

• 

Do not override or disable electrical or mechanical interlocks. 

Summary of Contents for Baby Fold

Page 1: ...GERA Baby Fold Operator Manual Revision December 2014...

Page 2: ...TION 4 ENVIRONMENTAL COMPLIANCE 4 WARRANTY 4 GENERAL NOTE 5 FOLD PACKAGE DIMENSION 5 PAPER SPECIFICATION 5 FLOOR SPECIFICATION 5 FOLDER VERSION 5 FOLD PROGRAMS 6 CONTROL PANEL 7 FAN FOLDING PROCEDURE...

Page 3: ...f you are not sure that your electrical supply meets the requirements please consult your local power company for advice WARNING This product must be connected to a protective grounded circuit This pr...

Page 4: ...let if you are unable to insert the plug into it Never use a plug that lacks a grounded connection terminal to connect the product to an electrical outlet Always follow all warnings and instructions t...

Page 5: ...operate this equipment Product Safety Certification This product is certified by following the Safety standards EN60950 Regulatory Information The CE mark applied to this product symbolizes GERA s de...

Page 6: ...ds a poor quality and increases a folding jams All types of paper different from the common must not be folded Mylar or polyester film must not enter the folder as they can also cause jams and damage...

Page 7: ...TRIC Step 1 Fan Fold 210mm 190mm 190mm 20mm Margin A4 3 times 99mm 210mm 190mm 210mm 297 or 305mm Map fold Lg 840mm 8 times 105mm 210mm Step 2 Cross Fold 297mm 297mm 297mm 297mm 297mm 305mm 210mm 305m...

Page 8: ...LED is on and the arrow key do not work for ejection procedure it means that all sensors are covered by paper It s necessary to uncover one of sensor to enable the ejection procedure Selection Key If...

Page 9: ...ock is face down leading Use the extractable support during cross fold procedure to avoid a wrinkled cross folded copy Using the collection tray copies Baby Fold Front Folder tray The copies fan folde...

Page 10: ...fold Before to perform the Automatic Eject Procedure try to pull back the paper manually from the bridge Automatic Eject Procedure Press the arrow key for 5 10 seconds to get out the copy the folding...

Page 11: ...of 19 panels for unlimited fold capability Cross Folding maximum length 1680 mm 8 panels 15 C 32 C 60 F 90 F 3 35 85 RH3 Paper weight 75 80 90 gsm Only for P4 steady or flashing program it s possible...

Page 12: ...e is 3mm Example 3times 9 297mm or 8 times 105mm 840mm 5 The folder often jams Paper curled or more than 90 gsm weight Wrong Fan folding Program Use paper not curled and 75 80 90 gsm weight Do not sel...