2
1.0 General safety precautions
IMPORTANT – Carefully read the entire instruction
manual before mounting and commissioning.
Please keep these instructions in a safe place and
instruct all users in the function and operation of the
energy arm.
Installation and service should only be carried out after
studying section 4 thoroughly.
Avoid detatching any factory-mounted parts, since it
impedes the commissioning of the equipment.
All electrical installations must be carried out by an
authorised electrician.
1.1 Danger
It is potentially deadly to touch the wires under the
Yellow cover shield.
Use extreme caution.
1.2 Area of application
The GEOVENT Energy arm is used where power, point
extraction and compressed air is needed at a
workstation.
The energy arm is NOT for use is areas categorized as
ATEX zones. Use only ATEX approved material.
1.3 Handling
Use protective gloves when transporting and installing
the energy arm.
1.4 Technical data
Power outlet: 1x230V, 13A
Supply: 3x400V, 16A
Compressed air: 2 outlets,
Extraction: High Vacuum with ø50 flap valve.
1.5 Construction
Wall c arm:
Painted steel, 50x100 profile, The
swivel joint of the console pivots up to 270°.
Protective box:
Powdercoated, galvanized steel.
Suspension:
Balancer and hose (GeoFlex P2A 1000)
for hose- and cables.
Hose for High Vacuum and cables are kept in the spiro-
duct on the arm.
2.0 Installation
The energy arm is supplied un-assembled. Depending
on the model it consists of one arm and spiro duct, one
protective box with outlets, one assembly kit with balan-
cer, bend with suspension and hose with hose clamps
and rubber bands for ducting.
Any ordered alterations will be stated on the order
confirmation/invoice.
Before mounting, please consider:
• Ample space for satisfactory use of the arm.
• Optimum height of installtion.
• Ducting and connections.
• First fasten the wall console of the arm on a
sturdy wall - e.g. a concrete wall.
• Mount arm on console.
• Fit spiro duct on the arm.
• Pass cables and hoses through spiroduct,
flexible hose and bend.(Remember to attach
hose clamp and rubber band prior to this.)
• Connect cables and hoses to the satellite.
• Suspend the satellite.
Balancer
Satellite box
with outlets
Bend with
suspension
Support arm
Spiro duct
Table of content
1.0 General safety precautions . . . . . . . . . . . . . . . . . . 2
1.1 Danger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
1.2 Area of application . . . . . . . . . . . . . . . . . . . . . . . . . 2
1.3 Handling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
1.4 Technical data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
1.5 Construction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
2.0 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
2.1 Power connection . . . . . . . . . . . . . . . . . . . . . . . . . 3
3.0 User instruction. . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
4.0 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
5.0 Liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
6.0 Declaration of conformity . . . . . . . . . . . . . . . . . . . . 4