7
Intake Assembly and Product Probe
The product intake assembly (Figure 1-4), combined with the product probe, is placed at a specific height
within the well. It is designed to recover the product layer from the water surface. A product float within the
probe rises and magnetically activates a switch in the PCM, turning on the pump as needed. The pump will
continue to run until the product float lowers and shuts off the system. A water float within the probe will also
shut off the PCM so that water is not pumped into the recovery tank.
Figure 1-4:
SWPS Intake Assembly with Product Probe