background image

 

 

 

Geocontrol 

 

PRO 

 

Installation

 

and

 

Operation

 

Manual

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Rev. 8/15/09 Part # 11150263  

Printed in the United States of America 

Summary of Contents for Geocontrol PRO

Page 1: ...Geocontrol PRO Installation and Operation Manual Rev 8 15 09 Part 11150263 Printed in the United States of America...

Page 2: ...2...

Page 3: ...ALLATION 7 CHAPTER 3 SYSTEM OPERATION 8 CHAPTER 4 SYSTEM MAINTENANCE 10 CHAPTER 5 SYSTEM TROUBLESHOOTING 11 CHAPTER 6 SYSTEM SPECIFICATIONS 13 CHAPTER 7 SYSTEM SCHEMATIC 14 CHAPTER 8 REPLACEMENT PARTS...

Page 4: ...ghly understand the CAUTION message A note icon indicates NOTE information Notes provide additional or supplementary information about an activity or concept NOTICES In order to ensure that your Contr...

Page 5: ...it has visible signs of significant physical damage other than normal wear and tear Notice for consumers in Europe This symbol indicates that this product is to be collected separately The following a...

Page 6: ...g a pressure of 100 psi This pressure allows the user to take samples from a depth to 180ft The controller offers a variable cycle timer for controlling the portable compressor s on time and off time...

Page 7: ...be wired directly to a 12V battery make sure to connect the positive red alligator clip to the positive red battery terminal and connect the negative black alligator clip to the negative black batter...

Page 8: ...push the water out of the pump Increase this time with increased depth to water and larger bladder pumps Decrease this time with lower depth to water and smaller bladder pumps Timer can be set from ap...

Page 9: ...no longer obvious For example if the well you are sampling has a depth to water of 23 feet you should not expect to see a reading on the pressure gauge much over 10 PSI When the discharge cycle begins...

Page 10: ...e cases or to remove aged caked on dirt and dust a mild soap and water solution can be applied to a soft cloth and used to clean the exterior surfaces of the Geocontrol Pro Do not soak or directly spr...

Page 11: ...et the unit sit in the OFF state for two minutes This will hard reset the electronic timer module If ambient temperatures are in excess of 104 F 40 C then disconnect from power and let sit in a cool l...

Page 12: ...er pump Remove the fluid discharge tube from the bladder pump While the compressor is running very little air discharge should be felt at the pump discharge fitting The pressure gauge on the front of...

Page 13: ...60 seconds Maximum pump depth 180 FT Maximum compressor pressure 100 PSI Duty cycle 40 on 60 off Ambient operational temperature 50 F 104 F 10 C 40 C Approximate weight 8 lbs FEATURES Variable pump D...

Page 14: ...14 Chapter 7 System Schematic...

Page 15: ...SS 17200078 12 16 SCREW PANEL MOUNT GAUGE 1 100PSI WITH MOUNTING CLAMP 11150254 2 17 HEX NUT 4 40 NYLOCK PPF062002 2 18 WASHER SS8 8 LOCK 17200081 4 19 SOLENOID GEOCONTROL PRO 11150249 1 20 SOLENOID M...

Page 16: ...garette Cable Adapter Set 77250000 12VDC Battery and Charger 11150254 Pressure Gauge 51150044 Cycle Module 11150258 Compressor 11150244 Knob 51150061 External Water Trap 51150063 AC Adapter 77250001 P...

Page 17: ...16...

Page 18: ...ial Authorization number RMA is required prior to return of any equipment to our facilities please call 800 number for appropriate location An RMA will be issued upon receipt of your request to return...

Page 19: ...66 BP 81150012 Geocontrol Pro w case These products comply with the directive 2004 108 EC EMC harmonized standard EN 61010 1 2001 12 07 emissions class A These products comply with harmonized standard...

Page 20: ...322 7242 email sales geotechenv com website www geotechenv com In the EU Geotech Equipos Ambientales S L Abat Escarr 12 Mollet del Valles Barcelona 08100 Espa a Tlf 93 5445937 email international geo...