background image

Wuhan Geosun Navigation Technology Co.Ltd

Website:

www.geosunlidar.com

Tel:+86 27 87504895

Add: 4F, Building D, Maker plaza No.8 West Maodianshan Road,

Fax:+86 27 87504895

East Lake Hi-tech Zone Wuhan City, China

Email: [email protected]

5

GS-260X Data Storage Instruction

GS-260X is used one TF SD cards, respectively

store POS, LIDAR and Image folder .

Each flight, the system will automatically create a folder named as the current time in
time, and store all the data collected in this folder directory.
Regarding the TF card, please use it according to the following terms:
[1] Please select a TF card above C10 U1 level.
[2] Approximately 5.5GB of data is generated every 10 minutes when runs LiDAR
system (in the triple echo mode). Please make sure that the remaining space in the TF
card is sufficient for next flights.
[3] When the TF card is connected to the computer, the computer system will pop up
a dialog box prompting that the storage device needs to be scanned. At this time, be
sure to select "Scan and Repair", otherwise the data in the TF card may not be read
and written normally.

GS-260X contains G64GB eMMC (The real capacity is 54 GB) Flash memory for
backing up the collected data to prevent data loss due to accidental damage of the TF
card.
If users need to read the data in eMMC Flash, please use USB type-C data cable.
(Please make sure the cable has a data transmission function. Some cables may only
have a power function. This type of cable cannot be used.) Connect the LiDAR unit to
the user's computer (the power cable does not need to be connected). The computer
will automatically recognize the TF card as a mobile storage device, and then can
perform data operations.
When each flight, it will automatically determine the remaining free space in the
eMMC flash memory. If the remaining space is less than 20GB, the system will
automatically delete the oldest data files until the remaining space is greater than
20GB.

Summary of Contents for gAirHawk GS-260X

Page 1: ... Tel 86 27 87504895 Add 4F Building D Maker plaza No 8 West Maodianshan Road Fax 86 27 87504895 East Lake Hi tech Zone Wuhan City China Email sales geosunlidar com 1 gAirHawk GS 260X uav LiDAR Scanning System Operation Manual Wuhan Geosun Navigation Technology Co Ltd V02 ...

Page 2: ...er GNSS and IMU positioning and attitude determination system Camera and storage control unit is able to real time dynamically massively collect high precision point cloud data and rich image information It is widely used in the acquisition of 3D spatial information in surveying electricity forestry agriculture land planning Interface Interface type Interface Model Function GNSS Antenna Interface ...

Page 3: ...Tel 86 27 87504895 Add 4F Building D Maker plaza No 8 West Maodianshan Road Fax 86 27 87504895 East Lake Hi tech Zone Wuhan City China Email sales geosunlidar com 3 GS 260X Side View and LED Indicators GS 260X Back View and LED Indicators 1 TF Card Slot 1 Type C Interface ...

Page 4: ...ke sure the base station starts collecting data one minute earlier than liDAR unit Please make sure the base station power off one minutes later after flights 6 Wait for the LiDAR system works in order The system will lock the satellite then LED indicators blink in normal The power indicator is on the GNSS indicator flashes one time in 1 intervals and the LIDAR indicator flashes one time in 1 inte...

Page 5: ...r the computer system will pop up a dialog box prompting that the storage device needs to be scanned At this time be sure to select Scan and Repair otherwise the data in the TF card may not be read and written normally GS 260X contains G64GB eMMC The real capacity is 54 GB Flash memory for backing up the collected data to prevent data loss due to accidental damage of the TF card If users need to r...

Page 6: ...ion is not good G LED Indicator Blinks Internal 0 5 S Light off Unlock the satellite 1Hz frequency blink the satellite is locked and internal Flash memory data are saved normally Steady blinks for more than 60s The system is abnormal please refer to troubleshoot instructions T LED Indicator Blinks Internal 2 S Light off no trigger signal output Blink According to user configuration it can be set a...

Page 7: ...ggered low level trigger normal high level low level when triggered Trigger signal pulse width 15ms 999ms The LiDAR is configured to be at a 3 second isochronous interval low level trigger and pulse width 15ms in default If you need to configure other trigger methods please contact our technical support staff The technical support staff will provide a configure ini file put this file into the root...

Page 8: ...e and LiDAR are firmly connected and the device is in an environment without any interference and the satellite signal is not blocked LIDAR indicator is off for a long time The LiDAR data will be read and stored only after the system completes the locking stars Please make sure the system locks the star normally If the LIDAR indicator is still off after more than 5 minutes please check whether the...

Reviews: