INSTALLATION
Geosense Thermistor Strings are manufactured to specific customer requirements with the
following variables:
-
•
Length of cable to the first Thermistor
•
Number of Thermistors
•
Spacing between each Thermistor
THERMISTOR LOCATION
ALONG CABLE
COLOUR CODING
1
GREEN
WHITE
2
BLACK
RED
3
BLACK
WHITE
4
BLACK
GREEN
5
BLACK
BLUE
6
BLACK
YELLOW
7
BLACK
BROWN
8
BLACK
ORANGE
9
RED
WHITE
10
RED
GREEN
11
RED
BLUE
12
RED
YELLOW
13
RED
BROWN
14
RED
ORANGE
15
GREEN
WHITE
16
GREEN
BLUE
17
GREEN
YELLOW
18
GREEN
BROWN
19
GREEN
ORANGE
20
WHITE
BLUE
21
WHITE
YELLOW
22
WHITE
BROWN
23
WHITE
ORANGE
24
BLUE
YELLOW
25
BLUE
BROWN
They should be installed in accordance with the specific project requirement.
It is therefore important that the correct reference is made & recorded for each sensor.
Below is the colour coding for multiple Thermistors up to a total of twenty six with
Thermistor number one being the nearest to the bare ended cable and from where readings
should be taken.