22
GEORG FISCHER +GF+¹
8
What to do if ...?
Cause
Locking screw tightened.
Wrong pipe diameter
set.
Nut on saw blade shaft
not tight enough.
Saw blade wrong way
round.
Pipe cutter not flanged
on. Flange surfaces are
dirty.
Pipe diameter wrongly
set.
Clamping lever not tight.
The restart inhibitor has
tripped.
Remedy
Loosen locking screw.
Set pipe diameter
correctly.
Tighten nut.
Fit saw blade correctly.
Inscription on saw blade
must face the pipe cutting
machine (see chapter 6).
Remove pipe cutter,
clean mounting parts
and flange surfaces, bolt
pipe cutter back on.
Adjust pipe diameter
(see chapter 6).
Tighten clamping lever.
Turn switch to "0", then
switch the pipe cutter on.
Problem
Pipe cutter will not turn.
Saw blade is not cutting
and is slipping.
Saw blade is not cutting.
Pipe is not being cut
concentrically.
Pipe is not being cut.
Motor not running.