32
This setting can be adjusted from 5% to 20%, but should remain
at the pre-set factory setting of 20%. If the user feels this setting
needs to be adjusted, they should discuss this with an authorized
GF Central Plastics representative first.
Select the desired short circuit value by using the (
▲
)(
▼
) buttons
and pushing START/OK (I) to confirm the setting. To cancel the
operation press STOP/ESC (O).
3.12 RESIST. TOLERANCE
This is the amount of allowable
tolerance allowed for the
coil resistance readings and
should be left at the factory
setting unless discussed with a
Georg Fischer Central Plastics
representative.
3.13 GPS MANAGEMENT
The options available in
this menu allow the user to
alter the GPS configuration
settings to improve accuracy
and account for location/
surroundings circumstances.
4. DATA MANAGEMENT
The MSA processor stores the fusion protocols for each fusion
cycle in the internal memory. This stored data is kept until the
operator deletes them or the memory is full.
To conform to ISO12176 standards, the MSA processor will store
(and provide for a later analysis) the following data: