57
APPENDIX H. MODEL 8032-27 AND LOAD CELL WIRING
Connect the “common” VW- conductor from the load cell to the 8032-27 by lifting up on the orange tab
located on the opposite side of the six black conductors, inserting the common conductor fully into the
8032-27 (Figure 26), and then pushing down on the orange tab until it snaps into place. Refer to Table 17
to identify which conductor carries the common VW- signal.
Figure 26 - Model 8032-27 Jumper Wire Assembly
10 pin Bendix
PT06A-12-10P
Function
3 Gage VW Load Cell,
Purple Cable
4 Gage VW Load Cell,
Purple Cable
6 Gage VW Load Cell,
Orange Cable
H
Common
White's Black*
Green
Blue
Table 17 - Common Conductor Chart
*
White's black and Green wires are switched on Geokon three-gage VW load cells prior to serial number 3313.
The following wiring chart details the connections between the load cell, the 8032-27, and the multiplexer board:
Multiplexer
Board
Vibrating Wire
with Thermistor
VW1+
VW Sensor #1
VW1-
8032-27
TH1+
Thermistor
TH1-
Thermistor
SHLD1
Shield Drain Wire
VW2+
VW Sensor #2
VW2-
8032-27
TH2+
-
TH2-
-
SHLD2
-
VW3+
VW Sensor #3
VW3-
8032-27
TH3+
-
TH3-
-
SHLD3
-
VW4+
VW Sensor #4
VW4-
8032-7
TH4+
-
TH4-
-
SHLD4
-
Table 18 - Multiplexer Board Wiring