APPENDIX A. SPECIFICATIONS
A.1 Model 4650 VW Settlement Sensor
Standard
Ranges
1
7, 17 m
Resolution
0.025% F.S.
Sensor
Accuracy
2
±0.1% F.S.
Temperature
Range
1
-20
°
C to +80
°
C (-4
°
F to +176
°
F)
Length x
Diameter
Reservoir: 152 x 51 mm (6 x 2")
Sensor: 191 x 35 mm (7.5" x 1.4")
Frequency
Range
1400-3500 Hz
Electrical
cable:
Model 02-335VT8, two shielded pairs, 22 gauge, 9.525 mm (3/8") diameter
polyurethane jacket with ground wire and integral 3.175 mm (1/8") diameter
polyethylene vent tube. Resistance 5.25 ohm/100 m (14.7 ohms/1000 ft.)
Liquid tubes:
Twin type 11 nylon tubes 6.35 mm (1/4") O.D. covered with one-millimeter
polyethylene jacket.
Liquid:
A de-aired 55/45 solution of distilled water mixed with commercial grade
propylene glycol. Specific gravity =1.041. Freezing point is –30
°
C (-22
°
F).
Desiccant
Capsules:
Geokon Model 4500-8
Table 1 - Specifications
1
Other ranges available on request
2
Laboratory accuracy. Total system accuracy is subject to site-specific variables.
A.2 Thermistor (see Appendix B also)
Range: -80 to +150 °C (-112 to +302 °F)
Accuracy: ±0.5 °C (0.9 °F)