10
When the desired elevation is reached, the cutting tool is activated by connecting the
pneumatic tube from the piezometer to a bottle of CO
2.
(CO
2
can be obtained locally from
any welding supply outlet.) The CO
2
bottle should have a pressure regulator that is set to
a pressure of at least 2.5 MPa (350 psi), with the shutoff valve closed (Figure 12).
Figure 12 - Pneumatic Cutter Equipment