20
APPENDIX A. SPECIFICATIONS
A.1 3400 Series Specifications
Input
Pressure Range
Vacuum to 400 bar (6000 psi)
Proof Pressure
2 x Full Scale(FS) (1.5 x FS for 400 bar, >=5000psi)
Burst Pressure
>35 x FS <= 6 bar (100psi)
>320 x FS <= 60 bar (1000psi)
>5 x FS <= 400 bar (6000psi)
Fatigue Life
Designed for more than 100 million FS cycles
Performance
Long Term Drift
0.2% FS/year (non-cumulative)
Accuracy
< 0.1%FS (Dependent on readout instrument)
Thermal Error
1.5% FS typical (optional 1% FS)
Compensated
Temperatures
-20
°
to 80
°
C (-5
°
to 180
°
F)
Operating
Temperatures
-40
°
to 125
°
C ((-22
°
to 260
°
) for elec. codes A, B, C, 1
-20
°
to 80
°
C (-5
°
to 180
°
F) for elec. codes 2, D, G, 3
-20
°
to 50
°
C (-5
°
to 125
°
F) for elec. codes F, M, P
Amplified units > 100C maximum 24 Vdc supply
Zero Tolerance
1% of span
Span Tolerance
1% of span
Mechanical Configuration
Pressure Port
see ordering chart
Wetted Parts
17-4 PH Stainless Steel
Electrical
Connection
see ordering chart
Enclosure
316 ss, 17-4 PH ss
IP65 for elec. codes A, B, C, D, G, 1, 2, 3
IP67 for elec. code “F”
IP68 for elec. codes M, P
IP30 for elec. code “3” with flying leads
Vibration
35g peak sinusoidal, 5 to 2000 Hz
Acceleration
100g steady acceleration in any direction 0.032% FS/g for one
bar (15 psi) range decreasing logarithmically to 0.0007% FS/g for
400 bar (6000 psi) range.
Shock
Withstands free fall to IEC 68-2-32 procedure 1
Approvals
CE
Weight
Approximately 100 grams (Additional cable: 75g/m)
Table 3 - Model 3400 Specifications