Improved protection using the LAB-3 can be had by placing the board in line with the cable as
close as possible to the installed piezometer (see Figure 8). This is the recommended method of
lightning protection.
Piezometer
Piezometer Cable
To Terminal Box/Readout Equipment
Lightning Arrestor Board (LAB-3)
(in special enclosure
Ground Stake
Ground Connection
accessible from surface)
Figure 8 - Recommended Lightning Protection Scheme