VERTICAL USE
Unfold the datum point on the integrated floor mount and set up the laser in its vertical (lay-down)
position.
The laser automatically self-levels in this position.
Set the ciruclar bubble as accurately as possible by using the two thumb screws. This ensures that the
instrument is set within its self-levelling range and the rotating beam is centered over its datum point.
All functions are identical to those in the horizontal position with following exceptions:
SLOPE
In SLOPE mode the X axis can be set manually, the Z axis is automatically self-levelled.
The TILT and / or V-W-S function can be activated.
If a slope has been set in the X axis and the laser is temporarily switched off, the axis will retain its
original position when the laser is switched on again.
MAN
In MAN mode both (X and Z) axes can be set manually.
The TILT and V-W-S function cannot be activated.
If a slope has been set in the X and Z axes and the laser is temporarily switched off, the X axis will reta-
in its original position when the laser is switched on again but the Z axis will self-level.
Set up the laser in the horizontal position first to re-set the self-levelling position.