background image

22

EN

F

OPTIONAL ACCESSORIES

Aluminium tripod FS 23

Length 105 -170 cm 

Weight 3,8 kg

Ref. no. 152

Elevating tripod FS 30-L

Length 90 - 285 cm 

Weight 8,2 kg

Ref. no. 156

Elevating tripod FS 30-M

Length 65 - 200 cm 

Weight 5,2 kg

Ref. no. 158

Elevating tripod FS 30-XL

Length 166 - 380 cm 

Weight 15,6 kg

Ref. no. 159

Wall and Ceiling Mount WH1

To fix the laser on a wall or 

ceiling. E.g. to make out drop 

ceiling.

Ref. no. 290600

Grade mount

To set slopes of 0 to 90° with 

rotating laser levels in manual 

mode Graduated slow motion 

screw Fits to any tripod with 

5/8“ connection

Ref. no. 290700

Telescopic levelling rod TN 20-Kombi

Graduation in mm.

For direct reading of height diffe-

rence.

Length 2,40 m 

Made of aluminium

Ref. no. 482

Telescopic levelling rod

TN 14/15

Made of aluminium

4 m - Ref. no. 484

5 m - Ref. no. 485

Summary of Contents for FL 110HA

Page 1: ...BEDIENUNGSANLEITUNG USER MANUAL MODE D EMPLOI www geo fennel de www geo fennel com www geo fennel fr DE EN FR FL 110HA...

Page 2: ...rch Nur ein sachge rechter Gebrauch gew hrleistet einen langen und zuverl ssigen Betrieb geo FENNEL Precision by tradition Inhaltsverzeichnis 1 Lieferumfang A 2 Nomenklatur B 3 Stromversorgung C 4 Bed...

Page 3: ...t 800 U min Stromversorgung Betriebsdauer 40h Li Ion Battery 40h 6 x AA Alkaline Temperaturbereich 10 C 50 C Laserdiode 635 nm Laserklasse 2 Staub Wasserschutz IP 66 Gewicht 2 1 kg Horizontallaser FL...

Page 4: ...Batterie 9 Kontrollleuchte Ladevorgang 10 Batteriefachverschluss 1 2 5 4 3 6 9 8 7 10 X X Y Y J I I I I C F D E G H B A BEDIENFELD A AN AUS Schalter B AN AUS LED C TILT Alarm Funktion D TILT LED E V W...

Page 5: ...k ausgestattet Wenn die Batterie zustandsanzeige H siehe Bedienfeld blinkt muss der Akku geladen werden Ladeger t mit Netz und Ladebuchse 7 am Ger t verbinden Die Ladekontrollleuchte 9 zeigt folgendes...

Page 6: ...es Stativbeines kommt es norma lerweise zu einer Ver nderung der Bezugsh he Die TILT Funktion verhindert dies das Ger t schaltet dann auch innerhalb des Selbstnivellierbereiches ab Wenn das Ger t nun...

Page 7: ...ALTUNG DES LASERSTRAHLS Mit den Tasten 4 oder der Fernbedienung kann der Laserstrahl sektionsweise abgeschaltet werden um z B St rungen bei Arbeiten mit mehreren Laserger ten auf einer Baustelle zu ve...

Page 8: ...ng an aus 11 Magnet 2 12 1 4 Gewinde f Klammer R ckseite LIEFERUMFANG Empf nger FR 45 Batterie Halteklammer Bedienungsanleitung Technische Daten Anzeige Display vorn Genauigkeit grob 10 mm Genauigkeit...

Page 9: ...rl ngerung der Lebensdauer der Batterie schaltet sich der Empf nger nach ca 5 Min ohne Anwendung automatisch ab EINSCHALTEN Knopf 5 dr cken Zum Empfangen des Laserstrahls den Empf nger langsam auf und...

Page 10: ...WH1 Zur Befestigung des Lasers an Wand oder Deckenprofilen Ideal im Innen ausbau z B zum Abh ngen von Decken Art Nr 290600 Neigungswinkeladapter F r Rotationslaser mit abschalt barer Automatik Neigung...

Page 11: ...iegen nicht der Garantie Der Garantieanspruch erlischt wenn das Geh use ge ffnet wurde Der Hersteller beh lt sich vor im Garantiefall die schadhaften Teile instand zusetzen bzw das Ger t gegen ein gle...

Page 12: ...ng ist aufzubewahren und bei Weitergabe der Lasereinrichtung mitzugeben LASERKLASSIFIZIERUNG Das Ger t entspricht der Lasersicherheitsklasse 2 gem der Norm DIN IEC 60825 1 2008 05 Das Ger t darf ohne...

Page 13: ...13 DE NOTIZEN...

Page 14: ...ation geo FENNEL Precision by tradition Contents 1 Supplied with A 2 Features B 3 Power supply C 4 Operation D 5 Receiver E 6 Optional accessories F 7 Safety notes G FUNCTIONS AND FEATURES FL 110HA is...

Page 15: ...800 rpm Power supply 40h Li Ion Battery 40h 6 x AA alkaline Temperature range 10 C 50 C Laser diode 635 nm Laser class 2 Dust water protection IP 66 Weight 2 1 kg Horizontal laser level FL 110HA Rece...

Page 16: ...Polarity indication of battery 9 Charging indication lamp 10 Battery cover lock 1 2 5 4 3 6 9 8 7 10 X X Y Y J I I I I C F D E G H B A KEYPAD A ON OFF switch B POWER LED C TILT alarm funktion D TILT...

Page 17: ...y pack If the battery warning indicator H is flas hing the battery needs to be charged Connect the charger to socket 7 and the power supply system The charging indication lamp 9 is indicating RED batt...

Page 18: ...has changed by accident a height offset would be caused This will be avoided by the TILT alarm function Now if the level is disturbed the unit will not re level itself and stop rotating the laser dot...

Page 19: ...ON With buttons 4 or with the remote control the laser beam can be shielded in all four directions however in max three directions at the same time This avoids that several laser instruments on one co...

Page 20: ...12 1 4 mounting hole for clamp reverse side SUPPLIED WITH Receiver FR 45 battery clamp user manual 1 2 1 7 5 8 3 4 6 9 10 11 11 12 Technical Data Indication Front display Accuracy coarse 10 mm Accurac...

Page 21: ...ave battery power the receiver will automatically turn off if it has not received a laser scanning signal for 5 minutes USE OF THE RECEIVER Press the button 5 to switch the unit on Move the receiver u...

Page 22: ...o 159 Wall and Ceiling Mount WH1 To fix the laser on a wall or ceiling E g to make out drop ceiling Ref no 290600 Grade mount To set slopes of 0 to 90 with rotating laser levels in manual mode Graduat...

Page 23: ...arts or labour In case of a defect please contact the dealer where you originally purchased this product The warranty will not apply to this product if it has been misused abused or altered Without li...

Page 24: ...not use the instrument in explosive environment The user manual must always be kept with the instrument LASER CLASSIFICATION The instrument is a laser class 2 laser product according to DIN IEC 60825...

Page 25: ...25 EN NOTES...

Page 26: ...ani re ad quate Nous vous recommandons de lire avec soin tout particuli rement les consignes de s curit de ladite notice avant la mise en service de votre appareil Un emploi appropri est l unique moye...

Page 27: ...rotation 800 U min Alimentation autonomie 40h Li Ion batterie 40h 6 x AA alcalines Plage de temp rature 10 C 50 C Diode 635 nm Classe 2 tanche aux poussi re l eau IP 66 Poids 2 1 kg Laser rotatif FL 1...

Page 28: ...ontr le de l op ration de charge 10 Vis pour logement de piles 1 2 5 4 3 6 9 8 7 10 X X Y Y J I I I I C F D E G H B A CLAVIER A Bouton ON OFF B POWER LED C Indication de l tat des piles D R glage de d...

Page 29: ...ulateurs Li lon Il faut recharger l accumulateur d s l indication de l tat des piles H s allume Relier le chargeur au r seau lectrique et la douille de charge 7 Le voyant de contr le de charge 9 fourn...

Page 30: ...angement de la hauteur de r f rence La fonction de basculement emp che cet inconv nient l appareil s arr te m me s il se trouve l int rieur de la plage d autonivellement Mettre en marche l appareil et...

Page 31: ...ande on peut rendre le laser invisible sur certaines sections Cela peut tre utile si plusieurs lasers travaillent en m me temps sur un chantier La section en question est indiqu e par les diodes lectr...

Page 32: ...bride de latte LIVR COMME SUIT Cellule FR 45 support de cellule pile mode d emploi 1 2 1 7 5 8 3 4 6 9 10 11 11 12 Donn es techniques Affichage Ecran Pr cision grossi re 10 mm Pr cision normal 4 mm P...

Page 33: ...ation le r cepteur s arr te automatiquement apr s 5 min env afin de prolonger la dur e de vie des piles TRAVAIL SUR D T CTEUR Pressez le bouton 5 Pour capter le faisceau laser faire monter et descendr...

Page 34: ...e droit la garantie n est valable que si l utilisation du niveau a t conforme aux prescriptions En sont exclus l usure m canique et un endommagement externe par suite d usage de la force et ou d une c...

Page 35: ...cialiste autoris Ne pas enlever les indications d avertissement et de s curit port es sur le niveau Eviter que l instrument ne soit touch ou manipul par des enfants Ne pas utiliser le niveau dans un...

Page 36: ...5 Baunatal Tel 49 561 49 21 45 Fax 49 561 49 72 34 info geo fennel de www geo fennel de Technische nderungen vorbehalten All instruments subject to technical changes Sous r serve de modifications tech...

Reviews: