Wires between network switches :the audio output(AO) and video output(VO) of the first
network switch are connected with the corresponding audio input(AI) and video input(VI)
of the next network switch. The data wire COM¡LA¡LB should be connected accordingly.
PS-5E Power
PS-5E
Power
Extra Door Station
Door Station
Electrical
Lock
Note
£
CM-03NQH2-162
NETWORK SWITCH
POWER GND
AF
DATA TV+
TV-
MONI
GND
AF
DATA
TV+
TV-
+18V
LA
LB
AI1+
AI1-
VI1+
VI1-
AI2+
AI2-
VI2+
+18V
POWER GND
AF
DATA TV+
TV-
MONI +18V
VI2-
COM
AO1+ AO1- VO1+
VO1-
AO2+ AO2- VO2+
VO2-
LA LB COM
VI2-
VI2+
AI2-
AI2+
VI1-
VI1+
AI1-
AI1+
CM-03NQH2-162
NETWORK SWITCH
POWER GND
AF
DATA TV+
TV-
MONI
GND
AF
DATA
TV+
TV-
+18V
LA
LB
AI1+
AI1-
VI1+
VI1-
AI2+
AI2-
VI2+
+18V
POWER GND
AF
DATA TV+
TV-
MONI +18V
VI2-
COM
AO1+ AO1- VO1+
VO1-
AO2+ AO2- VO2+
VO2-
VO2-
VO2+
AO2-
AO2+
VO1-
VO1+
AO1-
AO1+
POWER
GND AF DA
T
A
TV+ TV
-
MONI +18V
POWER
GND AF DA
T
A
TV+ TV
-
MONI +18V
POWER
AF
DATA
GND
MONI
+18V
TV-
TV+
GND AF
DA
T
A
TV+ TV
-
+18V
Electrical
Lock
Input terminal from
conformity unit
CM-03NQH2-162 Network Switch
Connect with next
network switch
AFOUT
A+18V
AFIN
DA
T
A
AGND
MONI
V+18V
VGND
TVIN
TVOUT
AFOUT
A+18V
AFIN
DATA
AGND
MONI
V+18V
VGND
TVIN
TVOUT
1.T&R
2.MONI
3.AGND
4.+18V
5.VGND
6.TV
CN1
CN2
CN3
CN4
CM-03NLCH Module
d)Wiring among
CM-03NQH2-162 switch,CM-03NLCH module and door station
£
+DC-
¡
AC
¡
TRANSFORMER
Model
£
PS-5E
Input
£
230V
¡
50Hz
Output
£
18V 800mA
Notes:Used in indoor
+
-
GND
LK-
POWER
POWER
LK+
AF
DA
T
A
GND
MONI
+18V
TV
-
TV+
GND
LK-
POWER
POWER
LK+
AF
DA
T
A
GND
MONI
+18V
TV
-
TV+
POWER
GND
AF
DATA
GND
+18V
TV-
TV+
CM-02NLRG or
CM-02NLRG-C
1 2 3 4 5 6 7
AGND +18V VGND VGND TV
MONI
T&R
102
Indication
CM-03NLCH-162
Setup
A+18V AFOUT DATA AGND MONI V+18V VGND TVOUT
T&R
MONI AGND V+18V VGND TV
A+18V GND
T&R
MONI AGND V+18V VGND TV
A+18V
A+18V AFIN
DATA AGND MONI V+18V VGND TVIN
T&R
MONI AGNDV+18V VGND TV
A+18V GND
T&R
MONI AGND V+18V VGND TV
A+18V
TV
VGND
V+18V
AGND
MONI
T&R
T&R
MONI
AGND
+18V
VGND
TV
CM-02NLRH/CM-02NLRH-C
TV
VGND
+18V
AGND
MONI
T&R
MONI
AGND
V+18V VGND
TV
T&R
T&R
MONI
AGND
V+18V VGND
TV
A+18V
GND
CM-02NLRV/CM-02NLRV-C
A+18V
T&R
MONI
GND
V+18V
VGND
AGND
TV
103
104
T&R
AGND
WL-02NLFH
101
Module
¢
£
a)
CM-03NLCH-162 module and indoor phone
£
Wiring between module and indoor phone
Wiring between
12V
Power
12V
Power