1.5 Water circuit – description

Water circuit will be constructed with respect to the 

applicable norms and requirements.

Please see the specifications in sections 3.1. and 3.2

1.5.1 Requirements for the water circuit

Depending upon the materials used in the water circuit of 

the dwelling, incorrect material combinations can lead to 

corrosion damage due to galvanic corrosion.

This requires special attention with the use of galvanised 

components and components that contain copper

1.5.2 Dimensions

18

00

,5

37

-2

5

+

5

Ø 660

52

,5

A

A

68

85

6

13

69

SECTION A-A 

14

13

12

8

9

10

12

13

46

14

80

1

2

3

4

5

6

7

15

Vanvex R:

Supply air

1. 

Exhaust air

2. 

Circuit board

3. 

Condensate drain

4. 

Compressor

5. 

Magnetic valve

6. 

Non return valve

7. 

285 liter boiler

8. 

Service connecting 

9. 

1,5 kW electric heating element

10. 

Anode 

11. 

Cold water connecting 3/4” AG

12. 

Hot water circulation 3/4” AG

13. 

Hot water connecting contact 3/4” AG

14. 

High pressure switch

15. 

Summary of Contents for Vanvex R

Page 1: ...Installation Manual Vanvex R Domestic water heat pump Version V6 01 0408 GB...

Page 2: ...1 2 Electrical circuit safety instructions 8 2 1 3 Water circuit safety instructions 8 2 2 Delivery 8 2 3 Storage 8 2 4 Transport 8 2 4 1 Transport with forklift 8 2 4 2 Unloading the heat pump 8 2 4...

Page 3: ...le with the external addition of energy which takes place in the compressor In the vaporiser heat is absorbed from the air and refrigerant in gaseous form and fed to the compressor In the compressor t...

Page 4: ...changs is reserved 4 1 4 4 Refrigerant circuit Component overview No Description 1 Compressor 2 Condenser 3 Vaporiser 4 Centrifugal fan 5 Expansion valve 6 Drying filter 7 Pressure switc 8 Magnitic va...

Page 5: ...rosion damage due to galvanic corrosion This requires special attention with the use of galvanised components and components that contain copper 1 5 2 Dimensions 1800 5 37 25 5 660 52 5 A A 68 856 136...

Page 6: ...ng water filter DIN 1988 in hose service connection Safety valve p 6 bar to be mounted above the edge of the tank Valve at the lowest point for draining Installation Manual varmtvand warmwater Warmwas...

Page 7: ...lement 1 5Kw Heizstab 1 5Kw P H jtrykspressostat High pressure switch Hochdruckpressostat Skal jordforbindes jvt st rkstr msreglementet Must have earth connection Muss erdung haben Gul gr n yellow gre...

Page 8: ...Delivery The Vanvex R is delivered without water condense water tube and the safety equipment for the water circuit 2 3 Storage The Vanvex R must be stored upright without water and in its packaging...

Page 9: ...working pressure is 10 bars and the maximum working temperature is 65 C If necessary the supply pipe must be equipped with a pressure reduction valve and eventually a filter When installing the pipe...

Page 10: ...ood beneath 5 Carry on with removal c Remove the lower part of the palette while keeping the product in an angle position still with 2 pcs wood be neath 6 Product on floor with 2 pcs of tree 7 Removal...

Page 11: ...er column of at least 60 mm It is also possible to use other tight air traps like a tube with one turn If mounting of the air trap is omitted water damage or damage to the Vanvex Lite can arise If the...

Page 12: ...onnecting branch and aerate the tank by letting one of the hot water taps located at the highest elevation within the dwelling stand open until air no longer comes out with the water The container can...

Page 13: ...The right to make changs is reserved 13 Note...

Page 14: ...The right to make changs is reserved 14 Note...

Page 15: ...The right to make changs is reserved 15...

Page 16: ...erslev Tel 45 73 53 27 00 Fax 45 73 53 27 07 E Mail salg genvex dk Germany Novelan GmbH D 95359 Kasendorf Tel 49 0 92 28 99 60 7 0 Fax 49 0 92 28 99 60 7 189 E Mail info novelan de Great Britain Total...

Reviews: