background image

Genvex World Wide:

www.genvex.dk

Intelligent  ventilation  appliances  from 

Genvex

As a ventilation specialist, our spectrum of innovative ventilation 

engineering solutions: From passive ventilation appliances with 

highly efficient counterflow heat exchangers, to machines with 

integral  heat  pumps,  able  to  heat  and  cool  at  the  lowest  cost. 

Ceiling appliances for retrofitting in office and residential blocks 

are also available.
Want to know more? Write or give us a call!

Austria

J.Pichler Lufttechnik GmbH 

 

    

A-9021 Klagenfurt

Tel.: +43 (0) 463 / 3 27 69

Fax: +43 (0) 463 / 3 75 48

E-Mail: [email protected]

Belgium

 

Artiklima bvba

B - 9220 Hamme

Tel.: +32 (0) 52 41 25 41

Fax: +32 (0) 52 41 29 66

E-Mail: [email protected]

Croatia

Pichler & CO d.o.o.

10000 Zagreb

Tel.: + 385/ (0) 1/ 65 45 407 

Fax: + 385/ (0) 1/ 65 45 409

E-Mail: [email protected]

Denmark

Genvex A/S

DK - 6100 Haderslev

Tel.: +45 73 53 27 00

Fax: +45 73 53 27 07

E-Mail: [email protected]

Germany

Novelan GmbH

D-95359 Kasendorf

Tel.: +49 (0) 92 28 / 99 60 7-0

Fax: +49 (0) 92 28 / 99 60 7-189
E-Mail: [email protected]

Great Britain 

Total Home Environment Ltd

GB- Moreton in Marsh, GL 56 0JQ

Tel.: +44 (0) 845 260 0123

Fax: +44 (0) 1608 652490

E-Mail: [email protected]

Ireland / N.I.

ECO Systems Ireland Ltd

Co. Antrim BT54 6PH

Tel.: (UK 028) (ROI 048) +44 2076 8708 

Fax: (UK 028) (ROI 048) +44 2076 9781

E-Mail: [email protected]

Norway

 

Beam Sentralstøvsuger A/S

N - 1313 Vøyenenga

Tel.: +47 - 67 17 77 00

Fax: +47 - 67 17 77 10

E-Mail: [email protected]

Portugal

Iberterm

PT-4475-493 Nogueira Maia

Tel: +351 229 065 123/4

Fax: +351 229 065 125

E-Mail: [email protected]

Web: www.iberterm.com 

Slovenia

  

Pichler & CO d.o.o.

2000 Maribor

Tel.: +386/ (0) 2/460 13 50

Fax: +386/ (0) 2/460 13 55

E-Mail: [email protected]

Switzerland

  

SM-HEAG Klimatechnik AG

CH-8307 Effretikon

Tel.: +41 (0) 52 / 355 11 00

Fax: +41 (0) 52 / 355 11 05

E-Mail: [email protected]

Published by Genvex A/S, Sverigesvej 6, DK-6100 Haderslev

Presented by:

Summary of Contents for Vanvex R

Page 1: ...Installation Manual Vanvex R Domestic water heat pump Version V6 01 0408 GB...

Page 2: ...1 2 Electrical circuit safety instructions 8 2 1 3 Water circuit safety instructions 8 2 2 Delivery 8 2 3 Storage 8 2 4 Transport 8 2 4 1 Transport with forklift 8 2 4 2 Unloading the heat pump 8 2 4...

Page 3: ...le with the external addition of energy which takes place in the compressor In the vaporiser heat is absorbed from the air and refrigerant in gaseous form and fed to the compressor In the compressor t...

Page 4: ...changs is reserved 4 1 4 4 Refrigerant circuit Component overview No Description 1 Compressor 2 Condenser 3 Vaporiser 4 Centrifugal fan 5 Expansion valve 6 Drying filter 7 Pressure switc 8 Magnitic va...

Page 5: ...rosion damage due to galvanic corrosion This requires special attention with the use of galvanised components and components that contain copper 1 5 2 Dimensions 1800 5 37 25 5 660 52 5 A A 68 856 136...

Page 6: ...ng water filter DIN 1988 in hose service connection Safety valve p 6 bar to be mounted above the edge of the tank Valve at the lowest point for draining Installation Manual varmtvand warmwater Warmwas...

Page 7: ...lement 1 5Kw Heizstab 1 5Kw P H jtrykspressostat High pressure switch Hochdruckpressostat Skal jordforbindes jvt st rkstr msreglementet Must have earth connection Muss erdung haben Gul gr n yellow gre...

Page 8: ...Delivery The Vanvex R is delivered without water condense water tube and the safety equipment for the water circuit 2 3 Storage The Vanvex R must be stored upright without water and in its packaging...

Page 9: ...working pressure is 10 bars and the maximum working temperature is 65 C If necessary the supply pipe must be equipped with a pressure reduction valve and eventually a filter When installing the pipe...

Page 10: ...ood beneath 5 Carry on with removal c Remove the lower part of the palette while keeping the product in an angle position still with 2 pcs wood be neath 6 Product on floor with 2 pcs of tree 7 Removal...

Page 11: ...er column of at least 60 mm It is also possible to use other tight air traps like a tube with one turn If mounting of the air trap is omitted water damage or damage to the Vanvex Lite can arise If the...

Page 12: ...onnecting branch and aerate the tank by letting one of the hot water taps located at the highest elevation within the dwelling stand open until air no longer comes out with the water The container can...

Page 13: ...The right to make changs is reserved 13 Note...

Page 14: ...The right to make changs is reserved 14 Note...

Page 15: ...The right to make changs is reserved 15...

Page 16: ...erslev Tel 45 73 53 27 00 Fax 45 73 53 27 07 E Mail salg genvex dk Germany Novelan GmbH D 95359 Kasendorf Tel 49 0 92 28 99 60 7 0 Fax 49 0 92 28 99 60 7 189 E Mail info novelan de Great Britain Total...

Reviews: