The plumbing must be carried out according to regulations.

The piping can be made of flexible or solid materials. Care 

must be taken in respect to corrosion to avoid damages.

As for all pressurerized containers the heat pump must also 

be equipped with safety and non-return valves on the supply 

side.

Cold water inlet and hot water outlet is located on the back 

of the boiler (3/4” RG).

The maximum working pressure is 10 bar, and the maximum 

working temperature is 65°C.

If necessary, the supply pipe must be equipped with a 

pressure reduction valve and eventually a filter.

When installing the pipe work in the house any dirt in the 

pipes must be avoided. (Eventually flush the pipes with 

clean water before the heat pump is installed)!

When the pipes are connected make sure the pipes are not 

twisted. Use tools to hold the pipes against twisting!

If no recirculation is needed make sure the recirculation 

connector is closed!

Water connection

The following connections are located on the back of the 

heat pump:

Condensate drain hose

Cold water inlet 

Recirculation / Hot water outlet

No holes may be drilled. It can damage the 

winded condenser

Installation Manual

1. Screws to be removed (hexagonal head).

2. Screws to be removed

3. Removal of screws

Summary of Contents for Vanvex R OPTIMA 155

Page 1: ...Installation Manual Vanvex RS Domestic hot water heat pump Version V1 1008 GB...

Page 2: ...it safety instructions 8 2 2 Delivery 8 2 3 Storage 8 2 4 Transport 8 2 4 1 Transport with forklift 8 2 4 2 Unloading the heat pump 8 2 4 3 Transport with trolley 8 2 5 Placement set up 8 2 6 Connecti...

Page 3: ...emperature with the heat pump on C 55 Max water temperature with operation of heat pump and electrical heating element C 65 Domestic water boiler Material Steel specially enamelled Net volume Litre 28...

Page 4: ...nt overview No Description 1 Compressor 2 Condenser 3 Vaporiser 4 Centrifugal fan 5 Expansion valve 6 Drying filter 7 Pressure switc 8 Magnitic valve 9 One way valve Component overview Sensor Temperat...

Page 5: ...the heat pump have to have a safty valve and an automatic nonreturn valve The installation of the cold water connection shall be at the back of the unit 3 4 RG The max pressure is 10 bar and the max t...

Page 6: ...2 Reducing valve 3 Test valve 4 Contra valve 5 Manometer adapter 6 Circulation pump 7 Screwed connection with coupling 8 RG Connecting of cold water according to DIN 1988 Safety valve p 6 bar to be mo...

Page 7: ...PE MA4 T8 T7 T6 T5 PE N 13 12 11PE 10N 9F 8 6 5 4 3 2 1 X1 X3 X2 T1 6AH ICD 852xxx155 PC COM PE L PE Brun brown braun Bl blue blau Brun brown braun Sort black schwarz Brun brown braun Bl blue blau Gu...

Page 8: ...the safety equipment for the water circuit 2 3 Storage The Vanvex RS must be stored upright without water and in its packaging 2 4 Transport The Vanvex RS can not be tilted up to more than 45 C If thi...

Page 9: ...be equipped with a pressure reduction valve and eventually a filter When installing the pipe work in the house any dirt in the pipes must be avoided Eventually flush the pipes with clean water before...

Page 10: ...ood beneath 5 Carry on with removal c Remove the lower part of the palette while keeping the product in an angle position still with 2 pcs wood be neath 6 Product on floor with 2 pcs of wood 7 Removal...

Page 11: ...ain The water trap must contain a water column of at least 60 mm It is also possible to use other tight air traps like a tube with one turn If mounting of the water trap is omitted water damage or dam...

Page 12: ...fer to user manual 5 Fault finding The domestic hot water heat pump is equipped with followring safety devices 5 1 High pressure switch To prevent the compressor exceeding its range of application the...

Page 13: ...The right to make changs is reserved 13 6 Service Maintenance For maintenance refer to the operating instructions...

Page 14: ...The right to make changs is reserved 14 Note...

Page 15: ...The right to make changs is reserved 15...

Page 16: ...erslev Tel 45 73 53 27 00 Fax 45 73 53 27 07 E Mail salg genvex dk Germany Novelan GmbH D 95359 Kasendorf Tel 49 0 92 28 99 60 7 0 Fax 49 0 92 28 99 60 7 189 E Mail info novelan de Great Britain Total...

Reviews: