21

ELECTRICAL DIAGRAM  OPTIMA 270 –LEFT

1

1

1

2

2

2

3

3

3

4

4

X1

X2

X3

X5

LE

D

1

LE

D

2

1

1

1

2

2

2

3

3

3

4

4

4

3

2

1

4

3

2

1

L4

L3 A

L3 B

L3 C

L3 D

L20

L21

L17

L18

H7

H9

L17

L18

L3

L4

L1

L6

L8

L10

L11

L16

L2

L22

F1

F3

H1

H3

H

14

H

17

H7

H9

X1

MODBUS

Master

MODBUS

Display

MODBUS

CTS

RUN

ERROR

LAN OK

R

J45

ES

 2010 -

 O

pt

im

a 270

U

SB

-mi

ni

L

L

L

L

L

L

L

N

N

N

N

N

N

GN

D

GN

D

GN

D

GN

D

GN

D

GN

D

GN

D

GN

D

Sen

sor

3,

3V

GN

D

24V

D

C

24V

D

C

GN

D

GN

D

GN

D

GN

D

GN

D

24V

D

C

24V

D

C

A

A

B

B

GN

D

GN

D

0-

10V

0-

10V

Ta

cho

Ta

cho

Si

gna

l

Si

gna

l

Si

gna

l

0-

10V

Sen

sor

Sen

sor

Sen

sor

Sen

sor

Sen

sor

T8

T9

R1

R2

R3

R4

R5

C

R

2032

8A

2,

5A

5x

20m

m

5x

20m

m

N
L

GND

+24V

1
2
3

1
2
3

1
2
3
4

1
2
3
4

R

ot

or

 M

ot

or

+24V

GND

0-10V

L1

L6

L8

L10

L11

L16

GN

D

GN

D

GN

D

GN

D

24V

D

C

24V

D

C

GN

D

GN

D

GN

D

GN

D

24V

D

C

A

B

Si

gna

l

Si

gna

l

0-

10V

Sen

sor

Sen

sor

T8

T9

4

3

2

1

4

3

2

1

3

2

1

3

2

1

L

L

N

N

L2

GN

D

24V

D

C

A

B

1

1

2

2

3

3
4

1

1

2

2

3

3
4

X1

1

2

3

4

A

B

GN

D

+24V

D

C

Si

gna

l

G

ND

+24V

D

C

+24V

D

C

G

ND

Si

gna

l

Rh

JRS 16

-02

-2

02

1

Ve

rs

io

n 1

,1

X2

X3

A

B

GN

D

+24V

D

C

A

B

GN

D

24

23

22

21

1

2

3

4

L22

X5

M

ai

ns

 c

onnec

tion

1x

230V

 50H

z,

 L,

 N

, P

E

M

ax

: 10A

O

ut

put

 H

3 -

 S

er

vi

ce m

enu -

 E

C

13

Pr

eheat

 / R

eheat

 / A

lw

ay

s O

n

1x

230V

 50H

z

M

ax

.load 1800W

Aux

. r

el

ay

 H

17

1x

230V

 50H

z

O

N

LY

 c

ont

rol

 c

ur

rent

Sens

or

 T

8 F

ros

t

Sens

or

 T

7 E

xt

rac

t ai

r

Sens

or

 T

4 E

xhaus

t ai

r

Sens

or

 T

3 O

ut

door

 ai

r

Sens

or

 T

1 S

uppl

y ai

r

Sens

or

 T

9 O

pt

ion

Ex

ter

nal

 s

top

EC

 fan E

xt

rac

t ai

r

Bl

ue

Ye

llo

w

EC

 fan S

uppl

y ai

r

Bl

ue

Ye

llo

w

EC

 fan E

xt

rac

t ai

r

1x

230V

 50H

z

Bl

ue

Yel

low

/g

reen

H

um

idi

ty

 s

ens

or

 P

1

EC

 fan S

uppl

y ai

r

1x

230V

 50H

z

C

ont

rol

 s

ignal

 R

ot

or

M

odul

at

ing R

eheat

ing

M

odul

at

ing P

reheat

ing

Pot

ent

ial

 fr

ee i

nput

 

for

 opt

ional

:

H

um

idi

st

at

Ex

trac

tor

 hood

W

hi

te

W

hi

te

M

odbus

 M

as

ter

 /

ES

1048

Bl

ue

Yel

low

/g

reen

Yel

low

/g

reen

Yel

low

/g

reen

Br

own

Bl

ue

Br

own

Bl

ue

Fl

ow

 s

ens

or

 E

xt

rac

t ai

r

Fl

ow

 s

ens

or

 S

uppl

y ai

r

O

pt

im

a T

ouc

h D

is

pl

ay

 /

O

pt

im

a B

as

ic

 D

is

pl

ay

O

pt

im

a T

ouc

h D

is

pl

ay

 /

O

pt

im

a B

as

ic

 D

is

pl

ay

M

odbus

 M

as

ter

 /

ES

1048

M

odbus

 C

TS

Br

own

Bl

ue

G

re

en /

 B

lue

W

hit

e /

 Y

ell

ow

Br

ow

n /

 R

ed

LE

D

 1

 O

n =

 Int

er

net

 c

onnec

tion

LE

D

 2

 1 f

las

h     =

 E

xt

er

nal

 s

top

 2 f

las

hes

 =

 S

ens

or

 er

ror

 3 f

las

hes

 =

 H

um

idi

ty

 s

ens

or

 er

ror

 4 f

las

hes

 =

 F

an er

ror

 5 f

las

hes

 =

 S

ens

or

 F

ros

t er

ror

 6 f

las

hes

 =

 F

ire f

ai

lur

e /

 tes

t

 7 f

las

hes

 =

 F

ire f

ai

lur

e -

 D

am

per

 1

 8 f

las

hes

 =

 F

ire f

ai

lur

e -

 D

am

per

 2

 9 f

las

hes

 =

 F

ire f

ai

lur

e -

 B

ox

 1

10 f

las

hes

 =

 F

ire f

ai

lur

e -

 D

am

per

 3

11 f

las

hes

 =

 F

ire f

ai

lur

e -

 D

am

per

 4

12 f

las

hes

 =

 F

ire f

ai

lur

e -

 B

ox

 2

13 f

las

hes

 =

 R

ot

or

 al

ar

m

I/O

 P

C

B

Pl

eas

e ens

ur

e s

uf

fic

ient

 

ear

thi

ng of

 the i

ns

tal

lat

ion

Ser

vi

ce m

enu  E

C

 10 =

 R

ight

Yel

low

/g

reen

Yel

low

/g

reen

Bl

ue

Bl

ue

Bl

ue

Bl

ue

Br

own

Br

own

Br

own

Br

own

I/O P

CB

Bro

wn

Bro

wn

Bro

wn

Bro

wn

Br

ow

n

Br

own

W

hi

te

W

hi

te

W

hi

te

W

hi

te

W

hi

te

W

hi

te

W

hi

te

W

hi

te

Whi

te

Whi

te

Whi

te

Yel

low

/gr

een

Yel

low

/gr

een

Blue

Blue

Yel

low

Ye

llo

w

G

reen

Green

Bl

ue

Blue

Red

Red

G

reen

G

reen

Br

own

Br

own

R

ed

R

ed

R

ed

Bla

ck

Bla

ck

1

1

1

2

2

2

3

3

3

4

4

X1

X2

X3

X5

LE

D

1

LE

D

2

1

1

1

2

2

2

3

3

3

4

4

4

3

2

1

4

3

2

1

L4

L3 A

L3 B

L3 C

L3 D

L20

L21

L17

L18

H7

H9

L17

L18

L3

L4

L1

L6

L8

L10

L11

L16

L2

L22

F1

F3

H1

H3

H

14

H

17

H7

H9

X1

MODBUS

Master

MODBUS

Display

MODBUS

CTS

RUN

ERROR

LAN OK

R

J45

ES

 2010 -

 O

pt

im

a 270

U

SB

-mi

ni

L

L

L

L

L

L

L

N

N

N

N

N

N

GN

D

GN

D

GN

D

GN

D

GN

D

GN

D

GN

D

GN

D

Sen

sor

3,

3V

GN

D

24V

D

C

24V

D

C

GN

D

GN

D

GN

D

GN

D

GN

D

24V

D

C

24V

D

C

A

A

B

B

GN

D

GN

D

0-

10V

0-

10V

Ta

cho

Ta

cho

Si

gna

l

Si

gna

l

Si

gna

l

0-

10V

Sen

sor

Sen

sor

Sen

sor

Sen

sor

Sen

sor

T8

T9

R1

R2

R3

R4

R5

C

R

2032

8A

2,

5A

5x

20m

m

5x

20m

m

N
L

GND

+24V

1
2
3

1
2
3

1
2
3
4

1
2
3
4

R

ot

or

 M

ot

or

+24V

GND

0-10V

L1

L6

L8

L10

L11

L16

GN

D

GN

D

GN

D

GN

D

24V

D

C

24V

D

C

GN

D

GN

D

GN

D

GN

D

24V

D

C

A

B

Si

gna

l

Si

gna

l

0-

10V

Sen

sor

Sen

sor

T8

T9

4

3

2

1

4

3

2

1

3

2

1

3

2

1

L

L

N

N

L2

GN

D

24V

D

C

A

B

1

1

2

2

3

3
4

1

1

2

2

3

3
4

X1

1

2

3

4

A

B

GN

D

+24V

D

C

Si

gna

l

G

ND

+24V

D

C

+24V

D

C

G

ND

Si

gna

l

Rh

JRS 16

-02

-2

02

1

Ve

rs

io

n 1

,1

X2

X3

A

B

GN

D

+24V

D

C

A

B

GN

D

24

23

22

21

1

2

3

4

L22

X5

M

ai

ns

 c

onnec

tion

1x

230V

 50H

z,

 L,

 N

, P

E

M

ax

: 10A

Aux

. r

el

ay

 H

17

1x

230V

 50H

z

O

N

LY

 c

ont

rol

 c

ur

rent

Sens

or

 T

8 F

ros

t

Sens

or

 T

7 E

xt

rac

t ai

r

Sens

or

 T

4 E

xhaus

t ai

r

Sens

or

 T

3 O

ut

door

 ai

r

Sens

or

 T

1 S

uppl

y ai

r

Sens

or

 T

9 O

pt

ion

Ex

ter

nal

 s

top

EC

 fan E

xt

rac

t ai

r

EC

 fan S

uppl

y ai

r

EC

 fan E

xt

rac

t ai

r

1x

230V

 50H

z

Bla

ck

Bl

ue

Yel

low

/g

reen

H

um

idi

ty

 s

ens

or

 P

1

EC

 fan S

uppl

y ai

r

1x

230V

 50H

z

C

ont

rol

 s

ignal

 R

ot

or

M

odul

at

ing R

eheat

ing

M

odul

at

ing P

reheat

ing

Pot

ent

ial

 fr

ee i

nput

 

for

 opt

ional

:

H

um

idi

st

at

Ex

trac

tor

 hood

M

odbus

 M

as

ter

 /

ES

1048

Bl

ue

Yel

low

/g

reen

Yel

low

/g

reen

Br

own

Bl

ue

Br

own

Bl

ue

Fl

ow

 s

ens

or

 E

xt

rac

t ai

r

Fl

ow

 s

ens

or

 S

uppl

y ai

r

O

pt

im

a T

ouc

h D

is

pl

ay

 /

O

pt

im

a B

as

ic

 D

is

pl

ay

O

pt

im

a T

ouc

h D

is

pl

ay

 /

O

pt

im

a B

as

ic

 D

is

pl

ay

M

odbus

 M

as

ter

 /

ES

1048

M

odbus

 C

TS

Br

own

Bl

ue

Pl

eas

e ens

ur

e s

uf

fic

ient

 

ear

thi

ng of

 the i

ns

tal

lat

ion

Ser

vi

ce m

enu  E

C

 10 =

 R

ot

or

 Lef

t

Yel

low

/g

reen

LE

D

 1

 O

n =

 Int

er

net

 c

onnec

tion

LE

D

 2

 1 f

las

h     =

 E

xt

er

nal

 s

top

 2 f

las

hes

 =

 S

ens

or

 er

ror

 3 f

las

hes

 =

 H

um

idi

ty

 s

ens

or

 er

ror

 4 f

las

hes

 =

 F

an er

ror

 5 f

las

hes

 =

 S

ens

or

 F

ros

t er

ror

 6 f

las

hes

 =

 F

ire f

ai

lur

e /

 tes

t

 7 f

las

hes

 =

 F

ire f

ai

lur

e -

 D

am

per

 1

 8 f

las

hes

 =

 F

ire f

ai

lur

e -

 D

am

per

 2

 9 f

las

hes

 =

 F

ire f

ai

lur

e -

 B

ox

 1

10 f

las

hes

 =

 F

ire f

ai

lur

e -

 D

am

per

 3

11 f

las

hes

 =

 F

ire f

ai

lur

e -

 D

am

per

 4

12 f

las

hes

 =

 F

ire f

ai

lur

e -

 B

ox

 2

13 f

las

hes

 =

 R

ot

or

 al

ar

m

I/O

 P

C

B

Yel

low

/g

reen

Yel

low

/g

reen

Bl

ue

Bl

ue

Bl

ue

Bl

ue

Br

own

Br

own

Br

own

Br

own

Bro

wn

Bro

wn

Bro

wn

Br

ow

n

W

hi

te

Whi

te

Yel

low

/gr

een

Blue

Yel

low

Ye

llo

w

G

reen

Green

Bl

ue

Bro

wn

W

hi

te

Whi

te

Whi

te

Yel

low

/gr

een

Blue

Blue

Red

Red

Bl

ue

Ye

llo

w

Bl

ue

Ye

llo

w

W

hi

te

W

hi

te

G

re

en /

 B

lue

W

hit

e /

 Y

ell

ow

Br

ow

n /

 R

ed

I/O P

CB

Br

ow

n

W

hi

te

W

hi

te

W

hi

te

W

hi

te

W

hi

te

W

hi

te

G

reen

G

reen

Br

own

Br

own

R

ed

R

ed

R

ed

O

ut

put

 H

3 -

 S

er

vi

ce m

enu -

 E

C

13

Pr

eheat

 / R

eheat

 / A

lw

ay

s O

n

1x

230V

 50H

z

M

ax

.load 1800W

Bla

ck

Summary of Contents for ECO 360 R

Page 1: ...INSTALLATION MANUAL ECO 360 R Mechanical ventilation with passive heat recovery A...

Page 2: ...e system 12 Optimal initial commisioning of the system 12 System maintenance 13 Filters 13 Access to internal parts 14 Cleaning and inspection of rotary heat exchanger 15 Post heating surface 16 Fan 1...

Page 3: ...guidance on using the appliance in a safe way and under stand the dangers involved Children must not play with the appliance Cleaning and user maintenance must not be performed by children without su...

Page 4: ...g and reduced to a level necessary for efficient defrosting During defrosting an integrated modulating electric reheater ensures that the supply air temperature is maintained at an appropriate level T...

Page 5: ...vy structural component such as concrete It should also be ensured that no sound or vibra tions can be transmitted through materials in contact with the technical system If there is a risk of propagat...

Page 6: ...to the filter frame e g using elastic straps as shown in the picture below so that the filter is held in place and ensures 100 filtration Please note that this type of installation of the unit will r...

Page 7: ...there must be a clearance of at least 600 mm in front of the ECO 360 R 5 5 34 600 600 596 4 131 131 143 2 282 200 160 3 4 1 2 Right hand version 1 Discharge air 2 Extract air 3 Outdoor air 4 Supply ai...

Page 8: ...supply air to the right of the unit and a left hand version charac terised by the reheater being located in the supply air to the left of the unit It is possible to convert a right hand unit into a l...

Page 9: ...e duct installation it is recommended using 4 x 160 mm nipple connectors with double sealing lips Alternatively a 200 mm spiro pipe can be used which is connected directly to the outside of the ECO 36...

Page 10: ...grates should be placed on the north or east side of the house to achieve optimal comfort in homes flats It is recommended that the air intake should be located on the north or east side of the house...

Page 11: ...rovided with 50 mm of insulation finished with alumini um foil Supply air and exhaust air ducts routed through heated rooms in the home do not need to be insulated unless cooling a bypass or a geother...

Page 12: ...osition The intermediate valves are opened between 4 and 7 turns depending on how close they are to the unit 5 It is recommended setting the integrated post heating surface to a supply air temperature...

Page 13: ...means that the filters must be replaced cleaned The system is stopped by removing the appliance connec tor from the ECO 360 R or at the socket The filter plugs are opened and the filter drawer is pull...

Page 14: ...removed 1 Remove the screws from the front plate to access internal parts 2 Remove the protective plate covering the control board 3 Remove the 230V power cable and the control cable for the rotary ex...

Page 15: ...ng brushes unscrew the strips as shown in the picture below New brushes are fitted and the strips screwed back on BE CAREFUL not to overtighten the screws for the brush strips Check that the drive bel...

Page 16: ...do not use power tools to tighten the bolts as this may result in damage to the threaded connections Carefully tighten all the front plate bolts until the front plate is firmly seated on the housing...

Page 17: ...ets in general Check gaskets on the unit and make sure they are intact 12 months Supply air and exhaust valves Check for dirt in supply air and exhaust valves Clean as needed Check that the valves hav...

Page 18: ...l 21 071025 Converter 230V 24V DC 22 071069 Vibration damper 20x10 M6 PARTS LIST PART NUMBER STOCK NUMBER ITEM Gummifod 25x25 M6x18 068098 1 OPTIMA 270 Print 069875 2 IO print 069876 3 Samlet ventilat...

Page 19: ...an Clogged supply air filter Outdoor air grille clogged with dirt and leaves in the autumn or snow and ice in the winter Fuse on control board has blown Unit is defrosting supply air fan runs at reduc...

Page 20: ...utdoor air Sensor T1 Supply air Sensor T9 Option External stop EC fan Extract air Blue Yellow EC fan Supply air Blue Yellow EC fan Extract air 1x230V 50Hz Blue Yellow green Humidity sensor P1 EC fan S...

Page 21: ...fan Supply air EC fan Extract air 1x230V 50Hz Black Blue Yellow green Humidity sensor P1 EC fan Supply air 1x230V 50Hz Control signal Rotor Modulating Reheating Modulating Preheating Potential free i...

Page 22: ...2 4 6 8 10 12 14 0 5 10 15 20 25 30 Watt RPM Power consumption of display control board and rotor Heat and moisture recovery rotor according to 13141 7 0 10 20 30 40 50 60 70 80 90 100 1 3 5 10 15 20...

Page 23: ...DE COMMISIONING INSTRUCTIONS The declaration of conformity can be downloaded from www genvex com For further information on dismantling components with a view to disposal and recycling see illustrati...

Page 24: ...ilies At the same time our system is an important element when it comes to saving energy in homes and in society as a whole in fact you can recover up to 95 of the heat energy with a Genvex system All...

Reviews: