background image

Genvex World Wide:

www.genvex.dk

Intelligent  ventilation  appliances  from 

Genvex

As a ventilation specialist, our spectrum of innovative ventilation 
engineering solutions: From passive ventilation appliances with 
highly  efficient  counterflow  heat  exchangers,  to  machines  with 
integral  heat  pumps,  able  to  heat  and  cool  at  the  lowest  cost. 
Ceiling appliances for retrofitting in office and residential blocks 
are also available.

Want to know more? Write or give us a call!

Austria

J.Pichler Lufttechnik GmbH 

 

    

A-9021 Klagenfurt
Tel.: +43 (0) 463 / 3 27 69
Fax: +43 (0) 463 / 3 75 48
E-Mail: [email protected]

Belgium

 

Artiklima bvba

B - 9220 Hamme
Tel.: +32 (0) 52 41 25 41
Fax: +32 (0) 52 41 29 66
E-Mail: [email protected]

Croatia

Pichler & CO d.o.o.

10000 Zagreb
Tel.: + 385/ (0) 1/ 65 45 407 
Fax: + 385/ (0) 1/ 65 45 409
E-Mail: [email protected]

Denmark

Genvex A/S

DK - 6100 Haderslev
Tel.: +45 73 53 27 00
Fax: +45 73 53 27 07
E-Mail: [email protected]

Germany

Novelan GmbH

D-95359 Kasendorf
Tel.: +49 (0) 92 28 / 99 60 7-0
Fax: +49 (0) 92 28 / 99 60 7-189

E-Mail: [email protected]

Great Britain 

Total Home Environment Ltd

GB- Moreton in Marsh, GL 56 0JQ
Tel.: +44 (0) 845 260 0123
Fax: +44 (0) 1608 652490
E-Mail: [email protected]

Ireland / N.I.

ECO Systems Ireland Ltd

Co. Antrim BT54 6PH
Tel.: (UK 028) (ROI 048) +44 2076 8708 
Fax: (UK 028) (ROI 048) +44 2076 9781
E-Mail: [email protected]

Norway

 

Beam Sentralstøvsuger A/S

N - 1313 Vøyenenga
Tel.: +47 - 67 17 77 00
Fax: +47 - 67 17 77 10
E-Mail: [email protected]

Portugal

Iberterm

PT-4475-493 Nogueira Maia
Tel: +351 229 065 123/4
Fax: +351 229 065 125
E-Mail: [email protected]
Web: www.iberterm.com 

Slovenia

  

Pichler & CO d.o.o.

2000 Maribor
Tel.: +386/ (0) 2/460 13 50
Fax: +386/ (0) 2/460 13 55
E-Mail: [email protected]

Switzerland

  

SM-HEAG Klimatechnik AG

CH-8307 Effretikon
Tel.: +41 (0) 52 / 355 11 00
Fax: +41 (0) 52 / 355 11 05
E-Mail: [email protected]

Published by Genvex A/S, Sverigesvej 6, DK-6100 Haderslev

Presented by:

Summary of Contents for Combi 185

Page 1: ...Version 3 04 0208 GB User Manual Combi 185 L LS S Optima 310 Heat Pump and Domestic Hot Water...

Page 2: ...ry default scheme 10 2 Function 2 1 Controller Optima 310 11 2 2 Extra capacity 11 2 3 Operation safety 11 2 4 Warnings 11 3 Maintaining 3 1 Connecting to computer 12 3 2 Servicing 12 3 3 Water circui...

Page 3: ...when the display shows 1 T1 Supply air T2 Room T3 Fresh air T4 Exhaust air T5 Before coil cooling coil T6 Coil cooling T7 D water top T8 D water bottom T9 Solar collector R1 Compressor R3 Air heating...

Page 4: ...tank while the heat pump continues heating up the lower part to the operating temperature adjusted in menu point 5 8 R8 function This relay may be used as follows If the set point is 0 a circulation p...

Page 5: ...w suppl It is recommended that the supply air volume is adjusted to 20 lower than the set value in menu point 22 14 Filter change The control system contains an integral timer which counts the time fo...

Page 6: ...the relevant number of minutes 31 36 When the marker is pointing to menus between 18 and 23 the display heading changes to show actual changing point according to the following format Changepoint Wee...

Page 7: ...ly from the outside 38 Default values Please notice Before resetting the values please ensure that the actual set points are noted in the scheme page 43 Here is an option for re adjusting the set poin...

Page 8: ...8 Optima 310 53 Danish Select language 54 English Select language 55 German Select language 56 Polish Select language Danish 54 English 55 German 56 Polish Set point Operations menu Exit OK 5...

Page 9: ...esday Hours Minutes Le vel Red T2 1 2 3 4 5 6 7 8 9 10 Thursday Hours Minutes Le vel Red T2 1 2 3 4 5 6 7 8 9 10 Friday Hours Minutes Le vel Red T2 1 2 3 4 5 6 7 8 9 10 Saturday Hours Minutes Le vel R...

Page 10: ...Arrow Up or Arrow Down This will change the clock hour by 1 hour in the desired direction Contrast adjustment Contrast of the display can be changed by pressing the Info button while the program info...

Page 11: ...il has reached a temperature of app 5 C Then the magnetic valve closes again and the supply air fan and electric heating coil restart operation 2 2 Extra capacity Electric element If the hot water nee...

Page 12: ...n unbalance and thereby a higher noise level and abrasion of the fans Supply and extract valves Clean the valves by wiping with a dry cloth Make sure the valve does not rotate causing a change in the...

Page 13: ...t to check that the anode is intact at all times This should be done by inspecting the anode every 2 years and replacing it if it is corroded and measures only 6 10 mm in diameter To inspect the anode...

Page 14: ...e heating element dismantled The reset button can now be pressed Please notice Be careful not to damage or tear the cables to the control 4 3 Heat pump will not operate Unit has stopped Please control...

Page 15: ...15 Optima 310...

Page 16: ...erslev Tel 45 73 53 27 00 Fax 45 73 53 27 07 E Mail salg genvex dk Germany Novelan GmbH D 95359 Kasendorf Tel 49 0 92 28 99 60 7 0 Fax 49 0 92 28 99 60 7 189 E Mail info novelan de Great Britain Total...

Reviews: