Optima 310

Factory setting:

Date:

Date:

Date:

1

0

2  

21

3

0

4

0

5  

52

6

0

7

50

8

0

9

0

10

5

11

0

12

-10

13

50

14

3

15

0

16

30

17

0

18

5

19

0

20

5

21

40

22

70

23

100

24

35

25

55

26

70

27

0

28

1

29

0

30

0

31

1

32

1

33

0

34

0

35

0

36

0

37

0

38

0

39

0

40

0

41

0

42

0

43

-3

44

0

45

20

46

3

47

0

48

0

49

70

50

5

51

0,4

52

0

1.7 Factory default scheme

1.6 Special functions

Summertime:

Changing the clock between summer- and wintertime is 
done by simultaneously pressing “Enter” together with 
“Arrow Up” or “Arrow Down”. This will change the clock 
hour by 1 hour in the desired direction.

Contrast adjustment:

Contrast of the display can be changed by pressing the 
“Info” button while the program info screen is displayed. 
Use the arrows to adjust up or down. You can also enter 
menu 44, press OK and then hold the info button until the 
display reads “contrast adjust”, and adjust the contrast 
with “arrow up/arrow down” button. After 4 seconds the 
contrast adjusting menu is closed.

Program sub-version number:

Pressing “Arrow Up” when the program info screen is 
displayed will also show sub-version of the controller. Or 
it is possible to enter through the menu 44, press ok and 
then “arrow up”

Summary of Contents for Combi 185

Page 1: ...Version 3 04 0208 GB User Manual Combi 185 L LS S Optima 310 Heat Pump and Domestic Hot Water...

Page 2: ...ry default scheme 10 2 Function 2 1 Controller Optima 310 11 2 2 Extra capacity 11 2 3 Operation safety 11 2 4 Warnings 11 3 Maintaining 3 1 Connecting to computer 12 3 2 Servicing 12 3 3 Water circui...

Page 3: ...when the display shows 1 T1 Supply air T2 Room T3 Fresh air T4 Exhaust air T5 Before coil cooling coil T6 Coil cooling T7 D water top T8 D water bottom T9 Solar collector R1 Compressor R3 Air heating...

Page 4: ...tank while the heat pump continues heating up the lower part to the operating temperature adjusted in menu point 5 8 R8 function This relay may be used as follows If the set point is 0 a circulation p...

Page 5: ...w suppl It is recommended that the supply air volume is adjusted to 20 lower than the set value in menu point 22 14 Filter change The control system contains an integral timer which counts the time fo...

Page 6: ...the relevant number of minutes 31 36 When the marker is pointing to menus between 18 and 23 the display heading changes to show actual changing point according to the following format Changepoint Wee...

Page 7: ...ly from the outside 38 Default values Please notice Before resetting the values please ensure that the actual set points are noted in the scheme page 43 Here is an option for re adjusting the set poin...

Page 8: ...8 Optima 310 53 Danish Select language 54 English Select language 55 German Select language 56 Polish Select language Danish 54 English 55 German 56 Polish Set point Operations menu Exit OK 5...

Page 9: ...esday Hours Minutes Le vel Red T2 1 2 3 4 5 6 7 8 9 10 Thursday Hours Minutes Le vel Red T2 1 2 3 4 5 6 7 8 9 10 Friday Hours Minutes Le vel Red T2 1 2 3 4 5 6 7 8 9 10 Saturday Hours Minutes Le vel R...

Page 10: ...Arrow Up or Arrow Down This will change the clock hour by 1 hour in the desired direction Contrast adjustment Contrast of the display can be changed by pressing the Info button while the program info...

Page 11: ...il has reached a temperature of app 5 C Then the magnetic valve closes again and the supply air fan and electric heating coil restart operation 2 2 Extra capacity Electric element If the hot water nee...

Page 12: ...n unbalance and thereby a higher noise level and abrasion of the fans Supply and extract valves Clean the valves by wiping with a dry cloth Make sure the valve does not rotate causing a change in the...

Page 13: ...t to check that the anode is intact at all times This should be done by inspecting the anode every 2 years and replacing it if it is corroded and measures only 6 10 mm in diameter To inspect the anode...

Page 14: ...e heating element dismantled The reset button can now be pressed Please notice Be careful not to damage or tear the cables to the control 4 3 Heat pump will not operate Unit has stopped Please control...

Page 15: ...15 Optima 310...

Page 16: ...erslev Tel 45 73 53 27 00 Fax 45 73 53 27 07 E Mail salg genvex dk Germany Novelan GmbH D 95359 Kasendorf Tel 49 0 92 28 99 60 7 0 Fax 49 0 92 28 99 60 7 189 E Mail info novelan de Great Britain Total...

Reviews: