1. Product Features and Application 

     1) Features  

         Display is 3 types : Relative Power (RP), Accumulative Time (AT) 

         Output type : Relay contact 

         Standard panel : DIN 48 * 48 (LED display) 

     2) Applications 

          UV Lamp Monitoring / Water Sterilizer / Air Cleaner/ UV Hardener / UV Irradiator    

 

2. Product Specification and Configuration 

  1) Display Panel 

      - Panel Size: 48 

×

 48 

×

 85.5 

 , Panel cutting size : 45 

×

 45 

 (Tolerance : -0, + 0.5 

      - Power Supply:  85 ~ 265 VAC (50/60 

), Consumption : ≤ 3 W 

      - Operating Temperature: 0~50 

, Operating Humidity:  35 ~ 85 % RH 

      - Relay : 250AC 3A, 30VDC 3A. 

(1) Display Panel 

(4) Panel Cutting Size(mm) 

(2) Size of Display Panel 

[ Front view ] 

 2) Sensor Probe 

      Brown Line : #3, Black Line : #4, Blue Line : #5 

      

Information of Sensor Probe is in the enclosed Certificate of Quality (CQ) 

 

 3) Power cable and output cable are not included. 

(3) Size of Display Panel 

[ Side view ] 

48.00 

4

8

.0

0

 

8.20 

4

4

.0

0

 

85.50 

45.00 

(-0,+0.5) 

4

5

.0

0

 

(-

0

,+

0

.5

Summary of Contents for MG-06

Page 1: ...and Applications 2 Product Specification and Configuration 3 Product Installation 4 Operation 5 Relay Operation method 6 Relative Reaction Curves of UV Sensors 7 A S Request in Case of Product Failur...

Page 2: ...Configuration 1 Display Panel Panel Size 48 48 85 5 Panel cutting size 45 45 Tolerance 0 0 5 Power Supply 85 265 VAC 50 60 Consumption 3 W Operating Temperature 0 50 Operating Humidity 35 85 RH Relay...

Page 3: ...Sensor Probe is clean and dry If it is not clean then gently wipe it off with a lint free swab 2 Mounting the Display Panel a Mount the Display Panel in a temperature humidity of less than 50 122 35 8...

Page 4: ...E 01 and E 02 occurring Page 3 Mark Name Range Application C 01 Lower limited value of the UV low Alarm 0 100 According the actual requirement set the lamp low limited warming line In case the inspect...

Page 5: ...t flashing bit is shifted d Press Page down Key flashing number will be reduce by one press Press Set Key to chose the digit then press Page down Key chose the number Fix it by press Set Key 3seconds...

Page 6: ...Radiometer 6 a Connect AC power Terminal 9 and 10 and connect Sensor cable to terminal 5 Blue wire 3 Brown wire 4 Black wire Please refer to Fig 6 b Relay output terminal is 6 8 If you want to use rel...

Page 7: ...abnormal Green light means normal Power cable Power cable Green light ballast Capacitor 220 2kV Page 6 In normal status the relay will connect 6 and 7 the Green light will be ON and Red light will be...

Page 8: ...n 7 A S Request in Case of Product Failure 1 Should any failure is found in product please call the sales company or customer center for A S 2 Product warranty period is 1 year from the date of procur...

Reviews: