![GENTILIN C 330/03 Instruction Manual Download Page 19](http://html1.mh-extra.com/html/gentilin/c-330-03/c-330-03_instruction-manual_2213803019.webp)
20
B
MOD. C330/03
B
MOD. C330/24 - C330/50
A
EN
Rev. 01 - 05/2013 - Cod. CM31710 -
Instruction manual
Compressor Mod. C330
ABNORMALITIES
CAUSE
SOLUTION
The appliance restarts
numerous times even
without a utensil.
Leakages from the air pipe,
utensil or pneumatic sy-
stem.
•
Check that the pneumatic system is not damaged.
•
Check that the air pipe and utensils are intact as well as the
connections.
The utensil does not
emit air.
The tank is not pressurised.
•
Switch on the appliance and wait until the tank ills checking
the pressure of the relevant gauge.
Incorrect regulation of the
outlet pressure.
•
Check that the value displayed on the outlet pressure gauge
(A)
is greater than 0 (zero) bar.
The utensil is damaged.
•
Check that the utensil is intact and efective.
Fall of pressure in the
air tank.
Leakages in the air pipe,
utensil or the pneumatic
system.
•
Check that the pneumatic system is not damaged.
•
Check that the air pipe and utensil are not damaged.
•
Check that the appliance-air pipe and air pipe-utensil con-
nections are correct.
•
Check that the condensate pump is securely closed
(B)
.
Safety valve interven-
tion.
Pressure switch fault.
•
Contact an authorised Supplier.
Ai r loss f rom the pres-
sure switch when ap-
pliance is of.
Unclean or worn return
valve.
•
Contact an authorised Supplier.
The appliance vibra-
tes and/or emits lots of
noise.
Mechanical fault.
•
Contact an authorised Supplier.
Frequent start-ups and
low performance.
Unclean air ilters.
•
Carry out ilter cleaning (see Paragraph 31).