NOTE:

Units with battery back-up will not provide power or transmit

an alarm to other AC only units in the event of an AC power failure.

All battery back-up units in tandem with good batteries will operate

normally during an AC power failure a minimum of 24 hours

.

MOUNTING: PLATE & CO ALARM

1. Lace the connector through the provided mounting plate and

secure the plate to the junction box.

2. Plug the wire connector into the CO alarm base.

Figure 12

Figure 13

3. Place device up to mounting plate, rotating it clockwise until

device firmly snap locks into place. Keep CO alarm parallel to

the mounting plate so tabs on plate seat correctly into device.

4. Remove dust-cover after all construction is complete. Dust-

cover must be removed prior to power being supplied to the

CO alarm. If the dust-cover is not removed, operation of CO

alarm will be inhibited.

NOTE:

Remove dust-cover before operating CO alarm

PUSH BUTTON

FOR SELF TEST.

PUSH BUTTON

AND HOLD UNTIL

DEVICE ALARMS

FOR

FUNCTIONAL

TEST

POWER ON

INDICATOR

Figure 14

550-0498

Pg. C-6

CO INDICATOR

5. Press and release button for self test feature. Results of test:

Alarm is silent - CO Alarm is in good working condition

1 Chirp - Low battery. Replace battery following instructions in

Battery Installation Section

2 Chirps - CO Alarm has become dirty or defective or there is a

large influx of CO. Clean (refer to Maintenance Section or

warranty return.

3 Chirps - CO Alarm is at end of life and must be replaced.

CHECKOUT & TROUBLESHOOTING

1. Supply house power to the CO alarm, green indicator will be on.

The red indicator light should flash approximately every 15-30

seconds, showing that the CO alarm is operating properly.

2. If red light is not flashing or the green LED is not on:

a. Check that AC power is working.

b. Check that the battery is installed.

c. Push test button. Alarm will go into self test mode.

d. Check the connector plug and wire connections. NOTE: Be

sure you turn off power before checking wire connections.

e. If the power supply and wiring check out, but the red light does

not flash or the green LED is still off, return the unit to the

manufacturer. See TO RETURN A CO ALARM section.

3. When powering up devices in a tandem installation and all

the alarms sound immediately, inspect all devices for a solid

green LED. Verify wiring of units, if wiring checks and problem

remains the devices with flashing red LED are the trouble units

and should be replaced.

IF YOUR CO ALARM SOUNDS

Actuation of the CO alarm (temporal 4 tone) indicates the

presence of carbon monoxide (CO) which can kill you. If the

CO alarm sounds, do not ignore the unit!
Enclosed with the unit are two (2) labels to add the telephone

numbers of the emergency service provider and a qualified

technician. Once CO alarm is installed, place one (1) label next

to the CO alarm and place the other label near the fresh air

source at your prearranged meeting place after leaving the

house.
IF THE ALARM SIGNAL SOUNDS:

1. Operate the Test/Reset button. While the alarm has been reset,

the device will continue to monitor the air for the presence of CO.

If the alarm sounds again after 5 minutes there are CO levels that

are potentially dangerous.

2. Call emergency services, fire department or 911. Write the

number of your local emergency service here:

Do not tandem using both the red/yellow wire and brown/yellow

wire. Only 1 tandem interconnect wire is needed between units.

CAUTION:

Failure to observe any of the conditions set forth may

cause system malfunction and damage to the alarm.

BATTERY INSTALLATION

1. Locate side mounted battery drawer.

2. Open battery drawer by firmly pulling on side lip, then sliding

battery drawer open.

3. Insert battery into drawer, terminal side first. Take care to make

sure the appropriate terminal is aligned correctly, (+) terminal on

battery to (+) terminal on alarm metal contact and (-) terminal on

battery to (-) terminal on the alarm metal contact.

4. Rotate battery into drawer and close drawer. Note: the battery

drawer will not close if the battery is installed incorrectly.

5. Slide battery drawer shut until it is snapped into place.

6. Use only Duracell MN 1604 battery with the CO1209 CO alarm.

3. Immediately move to fresh air - outdoors or by an open door or

window. Meet at prearranged meeting place after leaving the

house. Verify all persons are accounted for. Do not re-enter

premises or move away from the fresh air until the emergency

responder has arrived, the premise has been aired out and the

CO alarm remains in normal condition.

4 After following steps 1-3, if the CO alarm reactivates within a 24-

hour period, repeat steps 1-3 and call a qualified appliance

technician to investigate for sources of CO from fuel-burning

equipment and appliances as well as inspect for proper operation

of this equipment. If problems are identified during this inspection

have the equipment serviced immediately. Note any combustion

equipment not inspected by the technician and consult the

manufacturers’ instructions, or contact the manufacturers directly

for more information about CO safety and this equipment. Make

sure that motor vehicles are not and have not been operating in an

attached garage or adjacent to the residence. Write down the

number of a qualified appliance technician here:

NOTICE!

“ALARM - MOVE TO FRESH AIR”

If you hear the CO alarm horn and the red light is flashing, move

everyone to a source of fresh air. DO NOT unplug the alarm!

NOTICE:

Alarms have various limitations. See “General

Limitations of CO Alarms” for details.

Summary of Contents for Smarter Vision CO1209 Series

Page 1: ...exposed to a critical level of CO measured in parts per million or ppm within a specified time measured in minutes This CO alarm features a permanently installed sensor an indicator light and an 85dBA...

Page 2: ...other appliances may also prevent alert persons from hearing the alarm horn This device is not intended for people who are hearing impaired CO alarms are not a substitute for life insurance Though th...

Page 3: ...cupiable level of a dwelling unit including basements excluding attics and crawl spaces 3 Other locations where required by applicable laws codes or standards The installation of additional CO alarms...

Page 4: ...DO NOT INSTALL THIS CO ALARM In garages kitchens furnace rooms or in any extremely dusty dirty or greasy areas Closer than 15 feet 4 6 meters from a furnace or other fuel burning heat source or fuel b...

Page 5: ...1125 feet between the first and last CO alarm NOTES ON TANDEM INTERCONNECTING MODELS DO NOT connect Gentex CO alarms to other manufacturers CO alarms No more than 12 Gentex models CO1209 may be tande...

Page 6: ...to add the telephone numbers of the emergency service provider and a qualified technician Once CO alarm is installed place one 1 label next to the CO alarm and place the other label near the fresh ai...

Page 7: ...en using any of these materials near the alarm make sure the room is well ventilated The CO alarm is not washable DO NOT submerge the alarm in water Water can affect the sensor causing permanent damge...

Page 8: ...entex postage prepaid You must also pack the CO Alarm to minimize the risk of it being damaged in transit You must also enclose a return address CO Alarms returned for warranty service should be sent...

Reviews: