background image

 

47 

 

 

 

 

Diagram

 

 

Model

 

 

Order Number

 

Box 

Quantity

 

 

 

 
 

 

ADF 

Welding 
Lens Kit 

(Complete) 

 
 
 
 

 

PR02111SP

 

 
 
 
 

 

1

 

 

 

 
 

Welding 

Lens 

Passive 

Shade 10 

Complete Kit 

 
 
 
 

PR02118SP

 

 
 
 
 

1

 

 
 

Refer to Lens diagrams page above 

Welding Lens 

Outer Cover 

– 

for ADF and 

Passive 

Lenses 

 
 

PR02117SP

 

 
 

1 (10/Pk)

 

 

Refer to Lens diagrams page above 

ADF Welding 

Lens Retainer 

Clip 

 

PR02112SP

 

 

1

 

 

Refer to Lens diagrams page above 

 

Inside Cover 
for ADF lens 

 

PR02113SP

 

 

1 (10/Pk)

 

 

Refer to Lens diagrams page above 

Shade 10 

Passive Lens 

– Filter Plate 

only 

 

PR02115SP

 

 

1 (10/Pk)

 

 

Refer to Lens diagrams page above 

Retaining 

Clip/Spring for 

Passive Lens 

 

PR02116SP

 

 

1

 

 

 

 

Visor 

Assembly 

ANSI Z87.1 + 

(High Impact) 

(Supplied with 
Attachment kit 

PR02950) 

 
 
 

 

PR02050SP

 

 
 
 

 

4

 

Summary of Contents for PureFlo 50ESM+

Page 1: ...Purifying Respirator PAPR Models 50ESM and 60ESM INSTRUCTIONS FOR USE USA Canada Rev 2 December 2017 Gentex Corporation 324 Main Street Simpson PA 18407 USA Telephone 570 282 3550 Fax 570 282 8555 Tol...

Page 2: ...NED 2 2 1 POWERED AIR PURIFYING RESPIRATOR PAPR 7 2 2 2 FILTER S AND CARTRIDGE S 7 2 2 3 RECHARGEABLE BATTERY PACK 7 2 2 4 BATTERY CHARGER 7 2 2 5 VISOR LOCK 7 2 2 6 STORAGE BAG 7 2 2 7 INSTRUCTIONS F...

Page 3: ...RIDGE INSTALLATION 14 3 2 5 FILTER OR CARTRIDGE REMOVAL 15 3 3 DONNING THE DEVICE 16 3 4 SWITCHING ON THE DEVICE 18 3 5 USE WHEN THE FACESHIELD IS RAISED 20 3 6 DURING USE 21 3 6 1 WARNINGS 22 3 7 AFT...

Page 4: ...R CHARGING THE BATTERY PACK 35 5 3 4 REPLACING THE FILTER OR CARTRIDGE 36 6 TRANSPORT 37 7 STORAGE 37 8 DISPOSAL 38 9 TECHNICAL DATA 39 10 RESPIRATORY APPROVAL LABEL 42 11 FILTER APPROVAL LABEL 43 12...

Page 5: ...only genuine Pureflo spare parts and accessories or the proper functioning of the product may be impaired Do not use a faulty or incomplete product Do not modify the product Materials that may come i...

Page 6: ...ipped with a High Efficiency Particulate Air HEPA HE filter order number PR02020SP they are effective against solid and liquid aerosols particulates When equipped with an HE HF HC cartridge order numb...

Page 7: ...isor lock insertion channel in the main chassis 4 Ensure the visor locking channel is facing down toward the top of the visor and fully insert the tail end of the visor clip into the slot of the unit...

Page 8: ...thable air The device continuously takes in ambient air through the filter The filter absorbs harmful particulates In this way the ambient air is recycled and finally reaches the face breathing zone T...

Page 9: ...a warning is triggered 2 4 Intended use When equipped with a HE filter Order number PR02020SP they protect against solids and liquid aerosols particulates When equipped with an HE HF HC cartridge Ord...

Page 10: ...andards whichever is lower in unventilated areas outside the intended temperature range of 40 F to 105 F 5 C to 40 C WARNING Immediately exit the contaminated area if any of the low battery or low air...

Page 11: ...ed tops comply with the High Visibility requirements of ANSI ISEA ZZ89 1 2014 Eye Protection ANSI ISEA Z87 1 2015 Impact Rated Z87 Hearing Protection ANSI US EPA Regulation 40 CFR Part 211 Subpart B F...

Page 12: ...amaged replace them before proceeding Confirm that the battery packs are fully charged and charge is sufficient for duration of the work period Visually inspect the neck cape material for damage Check...

Page 13: ...nnect the batteries to the chargers as shown below and with chargers plugged into a 120V electrical outlets Charge batteries The battery charger contains an LED This LED will display the following inf...

Page 14: ...outlet or power source NOTICE Always disconnect the charger from power supply if not in use The nominal recharge time for a battery pack is 2 5 hours Completely discharged batteries may require more t...

Page 15: ...xtremes may alter batteries charging characteristics DO NOT place charger near sources of sparks or other possible causes of ignition Batteries on charge may emit EXPLOSIVE hydrogen gas WARNING Failur...

Page 16: ...25 3 2 3 Headband position The position of the headband assembly can be moved backwards to improve balance of the unit See below...

Page 17: ...ockwise to engage the thread and then tighten in direction 2 clockwise to fit the filter on the respirator 2 Take care not to cross thread the filter 4 shows the correct gap between the filter and the...

Page 18: ...until the LED status indicator on the right inside of the helmet has illuminated green Adjust the wearing height by adjusting the crown strap of the headband see 3 2 3 Illustration 1 This may be more...

Page 19: ...high speed particles thus creating a hazard to the wearer Do not hold or suspend the respirator by the neck cape or headband Adjust the neck cape using the toggle fastener to tighten the drawstring a...

Page 20: ...xygen may occur Noxious ambient air may also penetrate the helmet Drowsiness dizziness or other complaints Breathing becomes difficult Damage to the equipment An audible warming sounds An optical red...

Page 21: ...on Status LED is red Flashing fast Fast three 3 tones Low Airflow Status LED is red Flashing slow Slow two 2 tone Low Battery Status LED is red Flashing fast Fast three 3 tones Filter not fitted 3 7 A...

Page 22: ...r inlet is covered 2 Filter or cartridge is fully loaded with particles 3 No filter or cartridge is fitted 1 Check air filter remove obstruction 2 Change filter or cartridge 3 Install filter or cartri...

Page 23: ...attery pack s X X Charge rechargeable battery pack s X Replace filter cartridge X Check flow rate and warning devices X Replace face shield X Replace helmet shell X Rechargeable cycles 500 cycles 5 2...

Page 24: ...ring pad may be used Dry the unit with a clean lint free cloth do not use heat source Clean concussion strap crown net and comfort pads using a mild solution of household detergent and water Max 90 F...

Page 25: ...place an old or damaged visor on Pureflo 60ESM as per the instructions below Replace an old or damaged visor on Pureflo 50ESM P Series Pharmaceutical bump cap variant as per instructions below Ensure...

Page 26: ...k in the helmet Headband replacement Replace Remove the headband assembly as shown in section 3 2 3 illustration B Adjust the crown strap of the headband as shown in section3 2 3 illustration 1 Orient...

Page 27: ...f the user alternate filters and accessories Adjust the headband to achieve a snug fit by the adjustment knob Section illustration 3 Replace headbands at least every five 5 years or if deterioration o...

Page 28: ...battery pack See 3 2 2 5 3 4 Replacing the filter All filters and cartridges must be replaced when the LED indicator is illuminated red The red LED and audible alarm indicates that the HE HEPA filter...

Page 29: ...no particles enter the device through the suction inlet NOTICE For further advice and support on fitting and cleaning procedures contact Gentex Only perform maintenance tasks described in these Instru...

Page 30: ...capacity and number of charges 8 Disposal This product must not be disposed of as municipal waste It is therefore marked with the symbol on the left Batteries and rechargeable batteries must not be di...

Page 31: ...Factor APF1000 with neck cape per OSHA assigned protection factor federal register notice 71 50121 50192 dated 8 24 2006 Filter type Cartridge type High Efficiency Particulate Air HEPA filter Hydrogen...

Page 32: ...charge Operational life time after a full charge 6 hours minimum on 2 battery packs new fully charged battery Rated Voltage 6 V Rated Capacity 2 2 Ah Output Power 13 2WH Battery Charger Battery Charge...

Page 33: ...corp com Telephone 570 282 3550 10 Service while under warranty All parts and labor will be covered for a period of 1 year from date of purchase Contact Sales office for an order number and shipping d...

Page 34: ...3a except as noted 4 Batteries 2 5 6 Suspension system partial illustration 7 Visor Locking Clip lifting visor versions only PF60 ESM Respirator Hard hat Lifting Visor Single off on switch PR05801 ser...

Page 35: ...and Attachment kit 1 Secondary Visor Welding Shield Accessory PR02106SP Includes Visor Welding Shield with Shade 10 Passive Lens and Attachment Kit 1 Light Attachment Bar PR01085SP 1 Secondary Visor...

Page 36: ...Snood Aluminized Fabric PR02095SP or PR02096S P 1 16 Battery Multi charger PR02042SP 1 Visor Protector Overlay Disposable PR02545SP 6 Visor Protector PR02510SP 4 Visor Lock Clip PR02066SP 1 See secti...

Page 37: ...eding OSHA PEL or other applicable government occupational exposure limits whichever is lower NIOSH does not approve filters for nuisance level protection HE HF HC Cartridge NIOSH Approved as part of...

Page 38: ...17SP 1 10 Pk Refer to Lens diagrams page above ADF Welding Lens Retainer Clip PR02112SP 1 Refer to Lens diagrams page above Inside Cover for ADF lens PR02113SP 1 10 Pk Refer to Lens diagrams page abov...

Page 39: ...Attachment Kit for Visor Assembly PR02950SP 4 Welding Shield attachment kit PR01908SP 1 Neck Cape Black Material is fire resistant PR02475SP 2 Neck Cape White Integrity 1800 Fabric PR01470SP 2 Neck C...

Page 40: ...ber Box Quantity Quick Release Headband PR01602SP includes Head Lining Pads mounting plates screw set instructions See also Next Part 1 Single Battery Charger PR02330SP 1 Battery Pack PR05706SP 1 Fan...

Page 41: ...t illustrated Helmet Bag Color Black Embroidered with Pureflo Logo HB14BLP 1 Secondary Neck Cape Leather overlay accessory PR02475SP LC 1 Available by return to approved service center only or manufac...

Page 42: ...51 14 ESM NIOSH Respirator Approval Label NIOSH RESPIRATOR APPROVAL LABEL HERE...

Reviews: