background image

INSPECTION & MAINTENANCE 

This section contains instructions for organizational inspection and 
maintenance of the Mask Light Amplified Mic .

Perform the inspections listed in Table 1 each time the Mask Light Amplified 
Microphone requires inspection

To inspect the operation of the 
microphone, follow the instructions for the 
communication test set available for 28 VDC 
Electret Amplified microphones 

To inspect the operation of the light, connect 
the oxygen mask communications cable 
to an appropriate communications test set 
configured for 28 Volt operation.  Actuate the 
lip/tongue lever switch to ensure proper on/
off function. 

1

2

3

Step

Nomenclature

Inspect For

Repair

1

External Assembly

Cuts, punctures, tears, deterioration 
or dirty surfaces, proper seating of 
power cord strain relief, bent pins in 
connector

Clean or replace as 
necessary

2

Internal Assembly

Proper operation, damage, foreign 
matter

Clean or replace as 
necessary

3

Communications/ 
Power Cord 
Assembly

Cracks, breaks or damage, loose or 
bent connector pins, corrosion, condi-
tion of cord keeper, proper position on 
the breathing hose

If damage is found re-
place communications/ 
power cord assembly

Table 1 – Inspection and Maintenance

Summary of Contents for MASK LIGHT AMPLIFIED MIC

Page 1: ...1002682 00 REV A 2021 Gentex Corporation Gentex is a registered trademark of Gentex Corporation or its affiliates MASK LIGHT AMPLIFIED MIC QUICK REFERENCE GUIDE...

Page 2: ...the external assembly such that the screws match with the two outer holes on mask NOTE Do not remove rubber cover 1 Using two fingers to hold the screws in place push the external assembly into the ma...

Page 3: ...tom of the mask cavity when installed Align the internal assembly pins to match the inner holes in the mask 4 Press the internal assembly into place until the push pins snap together 5 Tighten the Phi...

Page 4: ...Oxygen Mask Regulator Helmet and Communications Test Set or other microphone test equipment 7 8 Follow these steps to operate the Mask Light Amplified Mic POWER ON OFF Use tongue switch to toggle the...

Page 5: ...te communications test set configured for 28 Volt operation Actuate the lip tongue lever switch to ensure proper on off function 1 2 3 Step Nomenclature Inspect For Repair 1 External Assembly Cuts pun...

Page 6: ...re good connection through proper torque of the two mounting screws B Replace communi cations power cord assembly 2 Momentary switch on microphone inoperative Replace internal assembly 3 Microphone is...

Page 7: ...for this product Part Number Description 1001682 00 Mask Light Amplified Microphone Assembly 1001682 02 External Assembly Mask Light Amplified Microphone Replacement Kit 1001682 01 Internal Assembly M...

Page 8: ......

Reviews: