GN-503

120VAC

GN-503F

120VAC

GN-503FF

120VAC

GN-503 AND GN-503F Wiring Diagrams

GN-503 Series Combination Smoke/CO Alarm

GN-503/GN-503F ADDITIONAL PRODUCT INFORMATION

THE GN-503F AND GN-503FF PRODUCT WIRING HARNESS IS NOT INTERCHANGEABLE.  THE GN-503F AND GN-503FF
MUST USE PROPER WIRING HARNESS.  PRODUCT WILL NOT FUNCTION  IF INCORRECT HARNESS IS USED.

DO NOT connect Gentex alarms to other manufacturers’ alarms.

Per NFPA 72, a maximum of 18 compatible smoke, heat, CO and/or combination smoke/CO alarms may be interconnected. No 
more than 12 of the 18 can be smoke alarms. 

All units connected in tandem MUST get their power from the same circuit, that is, all smoke alarms in tandem must be 
controlled by the same fuse or circuit breaker.

NOTICE: PER NFPA 72, A MAXIMUM OF 12 SMOKE/CO ALARMS OF GN-503 WITH THE RELAY OPTION (F) MAY BE 
TANDEM INTERCONNECTED.

The GN-503/GN-503F may be tandem interconnected with other Gentex tandem capable smoke alarms, CO alarms or smoke/CO
alarms.  To interconnect with Gentex 9000 Series, 7000 Series, 710CS Series, 7109CS Series, GN-200 Series & GN-300 Series
the LEGACY TANDEM WIRE must be used.  Refer to installation manual for detailed information.

C

CA

AU

UT

TIIO

ON

N:: RED/YELLOW & BROWN/YELLOW wire to be capped when not in use. This wire is for tandem connection only. Do not

connect to any other circuit. 

If a GN-503 Series or CO1209 Series unit is annunciating for a CO event, legacy products that are tandem interconnected will 
not activate and will remain silent.

If smoke alarm portion of device goes into alarm, all smoke alarms, CO alarms or combination smoke/CO alarms tandem wired 
will sound smoke alarm warning.

When both smoke and CO conditions are present, smoke condition will have priority and alarm will sound smoke annunciation.

PLUG

SMOKE/CO
ALARM

BLK

WHT 

RED / YEL

VIO

VIO / BLK

BLU

ORN

YEL

GRAY

GRAY

HOT

NEUT

POWER

TANDEM - LEGACY

ALARM
CONTACTS

ACCESSORY
ALARM
CONTACTS

INTERNAL
JUMPER

BRN / YEL

TANDEM 

ELECTRICAL

 

BOX

SMOKE/CO

ALARM

QUICK DISCONNECT

TYPE PLUG

HOT / BLACK

NEUTRAL / WHITE

TANDEM WIRE

BRN / YEL

SMOKE

ALARM

SMOKE/CO

ALARM

ELECTRICAL

 

BOX

ELECTRICAL

 

BOX

TANDEM WIRE

RED / YEL

(LEGACY)

(LEGACY)