Gentec SMARTEC STS1000 Installation Manual Download Page 6

6

STS1000 M / B/ BM

STS1500M M/ B/ BM

ELECTRONIC SINGLE TEMPERATURE BASIN 

TAP

ELECTRONIC SINGLE TEMPERATURE 45˚  

BASIN  TAP

STS2500 M / B/ BM

STS2520

ELECTRONIC SINGLE TEMPERATURE WALL 

MOUNTED TAP

    

ELECTRONIC WALL MOUNTED SOAP 

DISPENSER

Technical Drawings

GENTECH AUSTRALIA PTY. LTD.

sensor 

window

13.7

15

25

12.9

35

26.6

plug

Water Outlet

power supply 

input wire

sensor input wire

168.5

57.5

5

G1/2

G1/2

G1/2

Ø20

Ø22

Ø60

Ø38

45º

155

91.5

15.5

15.5

138.5

W

ater Inlet

90.6

M6

48.5

116.8

Ø30

Ø44

114

120

70

400

Ø25

Summary of Contents for SMARTEC STS1000

Page 1: ...RTEC Electronic 90 Basin Tap STS1000 M B BM Electronic 45 Basin Tap STS1500 M B BM Electronic Wall Mounted Tap STS2500 M B BM Electronic Sensor Plate STS3500 STS4500 M B BM Electronic Sensor Plate Kit...

Page 2: ...4 Technical Drawings 6 Installation Requirements 8 Unit Components 9 Remote Functions and Operations 10 General Connections 12 Taps Mounting Instructions 14 Soap Dispenser Instructions 16 Sensor Plate...

Page 3: ...d under licence by SAI Global Certification Services Pty Limited ACN 108 716 669 SAI Global 286 Sussex Street Sydney NSW 2000 GPO Box 5420 Sydney NSW 2001 This certificate remains the property of SAI...

Page 4: ...TAP ELECTRONIC SINGLE TEMPERATURE 45 BASIN TAP STS3000 M B BM STS4000 M B BM ELECTRONIC SINGLE TEMPERATURE SENSOR KIT WITH SPOUT ELECTRONIC SINGLE TEMPERATURE SENSOR KIT WITH SPOUT Product Range Use 3...

Page 5: ...t on the product to avoid product failure STS2500 STS1020 STS2520 ELECTRONIC SINGLE TEMPERATURE WALL MOUNTED TAP ELECTRONIC SOAP DISPENSERS MAINS POWERED ONLY STS3500 M B BM STS4500 M B BM ELECTRONIC...

Page 6: ...TURE BASIN TAP ELECTRONIC SINGLE TEMPERATURE 45 BASIN TAP STS2500 M B BM STS2520 ELECTRONIC SINGLE TEMPERATURE WALL MOUNTED TAP ELECTRONIC WALL MOUNTED SOAP DISPENSER Technical Drawings G1 2 G1 2 22 6...

Page 7: ...stralia com au STS1020 STS4500 M B BM ELECTRONIC SOAP DISPENSER ELECTRONIC SINGLE TEMPERATURE SENSOR STS3500 M B BM S3000 ELECTRONIC SINGLE TEMPERATURE SENSOR SPOUT 400 100 120 44 3 31 7 43 400 100 12...

Page 8: ...sance triggering and activate the sensor when installed out of the suggested minimum clearance See images bellow Installation MUST be by a certified plumber and adhere to AS3500 and manufacturer s rec...

Page 9: ...Optimum 350kpa Maximum 500kpa Temperature Minimum 10 C Maximum 50 C Unit components No Description Qty 01 Tap Body 1 02 Sensor 1 03 Foam Washer 1 04 Metal Washer 1 05 Back Nut 1 06 Flexible Hose 1 07...

Page 10: ...ant button to change the setting to Remote Functions Functions Grey Remote Black Remote STS9006 Adjusting Controller Set Product Type Sensor Range and Time Adjustment Sensor Adjustment range 100mm up...

Page 11: ...ygiene flushes button 4 Remote Operation When hands are in the sensor s range program turns ON Removing hands from the sensor s range will switch the sensor OFF See Figure 1 Default is for Sensor to s...

Page 12: ...y using the screws provided Ensure to have enough space between the wall and the fixing point FOR UNITS STS1000MB STS1500MB STS2500MB IMPORTANT INFORMATION Make sure to turn on the power first and the...

Page 13: ...remove your hands out of range water should stop within 2 seconds The maximum duration of continuous flow is 1 minute The default factory set distance is 5 15cms BATTERY CHANGE 1 The indicator light...

Page 14: ...nting Instructions 3 Place the Flange and the tap unit in the pre punched hole 30mm to 35mm in the counter top 4 From underneath the sink or basin fix rubber seal fixing plate and fixing nut with a sp...

Page 15: ...able followed by the flexi hose through the tap hole Finally insert the tap body 5 Replace washer and mounting nut and fasten to the hob 6 Replace G1 2 Nut to flexi hose 7 Attach flexi hose to water m...

Page 16: ...ing diagram for the pump installation FOR THE BENCH MOUNTED UNIT 1 Drill a hole 32mm in the counter top 2 Remove the locknut and Insert the sensor cable followed by the flexi tube through the tap hole...

Page 17: ...wall and tighten Do not compress or distort the bracket 2 Connect the sensor cable from the sensor plate 2 to the solenoid wire Use a conduit to feed the wire up to the sensor plate 3 Install the sens...

Page 18: ...tery power transformer Before Installation Before connecting water to the valve ensure to flush the line and remove all debris All fixtures must be installed using slim compression fittings Working pr...

Page 19: ...r plate by tightening the screws provided equally Fix the top screws first to ensure the plate is straight Note the screws have up to 45mm adjustment 7 Place the cover plate 4 to the sensor plate 3 Us...

Page 20: ...nlet marked connection Also check that the water connection turned on or running from the source should inspect the water pressure before connecting should be less than 500kPa 6 My tap is turning on e...

Page 21: ...me 2 2 8 completed credit card authorisation in the form set out in Schedule 2 to these conditions accepting liability in accordance with clause 2 6 if the product is not faulty 2 3 The Principal will...

Page 22: ...s under statute or general law as to merchantability description quality suitability fitness for purpose or otherwise 4 2 2 is not liable for loss of profit indirect consequential or incidental loss d...

Page 23: ...Day or is after 5pm on a Business Day in which case that communication will be deemed to have been received at 9am on the next Business Day 5 2 3 if emailed at the local time in a place of receipt of...

Page 24: ...MAR IM SMR03 MB 181119 info gentecaustralia com au www gentecaustralia com au Unit 6 20 28 Ricketty St Mascot Sydney NSW 2020 P 612 9319 4422 F 612 8088 7635...

Reviews: