For optimum operational life, the installation of a PRV set to 350kPa is recommended
1.
The sensor’s maximum range is 160mm
+/- 10%
2. To reprogram sensitivity disconnect the
sensor power cable from the solenoid
box and leave it for at least 20 seconds.
3. Connect power cable again and wait for the
sensor light to start flashing. Immediately,
place your finger on the sensor until
the light becomes solid. This allows the
sensor to enter in reprogramming mode.
4. Place your hand to the desired
position to adjust sensitivity and hold
it in position until the light turns off.
5. To set the sensor at maximum distance,
disconnect the power cable from
the solenoid box, and
repeat step
3
to enter in reprogramming mode.
•
Do not place anything in front of the
sensor and allow the light to turn off.
FOR ALL UNITS
PLUS1000BM, PLUS2500BM
Sensitivity Adjustment