BLIZZARD 400-800 C ENC
24
532104 - Rev.A
Tr
ansla
tion of the orig
inal instruc
tions
ENGLISH
1 2
Basic Programming
BASIC PROGRAMMING
Default
dF
DEFAULT:
Y
indicates that all the set values correspond to the defaults.
no
indicates that one or more set values are different from the
defaults.
Select
Y
if you wish to restore the default configuration.
Y
Ct
MASTER-SLAVE
CONFIGURATION (§ 10):
MA
= board in
MASTER
mode:
SL
= board in
SLAVE
mode:
L
i
If the board is in
SLAVE
mode, some functions will
not be displayed:
LO
,
PA
,
Pb
,
bu
,
PF
,
Ph
,
OP
,
t
,
IP
,
t1
,
Ob
,
SP
.
MA
LO
OPERATING LOGICS (§ 7.5):
E
= Semi-automatic
EP
= Semi-automatic Step-by-Step
A
= Automatic
AP
= Automatic Step-by-Step
S
= Automatic Safety
b
= Semi-automatic B
C
= Dead-man
E
PA
PAUSE TIME A
(displayed only with automatic logics)
It is the total opening pause time.
Adjustable from
00
to
59
sec, in 1 second steps.
If 59 is exceeded, the display changes to indicate minutes and
tens of seconds (separated by a dot) with adjustment in steps of
10 seconds, up to a maximum of 9 min and 50 s.
L
i
E.g.: if the display indicates
2.5
, the time is 2 min
and 50 sec.
20
Pb
PAUSE TIME B
(displayed only with automatic logics)
It is the partial opening pause time.
Adjustable from
00
to
59
sec, in 1 second steps.
If 59 is exceeded, the display changes to indicate minutes and
tens of seconds (separated by a dot) with adjustment in steps of
10 seconds, up to a maximum of 9 min and 50 s.
L
i
E.g.: if the display indicates
2.5
, the time is 2 min
and 50 sec.
20
FO
MOTOR POWER:
01
= minimum force
50
= minimum force
50
So
OPENING SPEED:
01
= minimum speed
10
= maximum speed
08
Sc
CLOSING SPEED:
Regulates the closing speed of the motor.
01
= minimum speed
10
= maximum speed
08
ro
DECELERATION DURING OPENING:
Sets the opening pre-limit switch deceleration space in cm
00
= minimum deceleration space
99
= maximum deceleration space.
50
BASIC PROGRAMMING
Default
rc
DECELERATION DURING CLOSING:
Sets the closing pre-limit switch deceleration space in cm
00
= minimum deceleration space
99
= maximum deceleration space
50
bu
BUS
DEVICE REGISTRATION:
L
i
--
M1
ELECTRIC MOTOR ACTUATION IN DEAD-MAN MODE
L
i
Mt
tL
SET-UP
L
i
St
AUTOMATION SYSTEM STATUS:
Y
To save and exit from programming mode.
no
To exit from programming mode without saving
Press button
F
to confirm; when finished, the display reverts to
the automation status display:
00
= Closed
01
= Open
02
= Stationary then opens
03
= Stationary then closes
04
= Paused
05
= Opening
06
= Closing
09
= Pre-flashing then opens
10
= Pre-flashing then closes
14
= Obstacle during opening
15
= Obstacle during closing
Y