6
Genie TZ-50
Part No. 133555
Operator’s Manual
Third Edition • Third Printing
General Safety
97551 A
Improper contact
with components
under any cover
will cause serious
injury.
Only trained maintenance personnel
should access compartments. Access
by operator is only advised when
performing Pre-operation Inspection.All
compartments must remain closed and
secured during operation.
Compartment access is restricted.
CAUTION
The operator is responsible for safe machine
operation.This includes:
1 Avoid hazardous situations.
2 Always perform a pre-operation inspection.
3 Always perform function tests prior to use.
4 Inspect the work place.
5 Only use the machine as it was intended.
Do not operate unless:
You read, understand and obey:
- manufacturer’s instructions and safety rules -
safety and operator's manuals and decals
- employer’s safety rules
- applicable governmental regulations
You are properly trained to safely operate this
machine.
DANGER
82479 B
Failure to read, understand and
obey the operator's manual
and safety rules will result in
death or serious injury.
82505 A
Crushing Hazard.
Contact with moving
parts will cause death
or serious injury.
Keep clear of elevated
components.
82558
1263140
46262
43617
97551
82505
82479
Manifold Side / Platform End TZ-50
TZ5006-1234
STOP
STOP
46262
43617
82558
97551
1263140
82479
82505
82558 B
Injection Hazard
Escaping fluid under pressure can
penetrate skin, causing serious injury.
Relieve pressure before disconnecting
hydraulic lines. Keep away from leaks
and pin holes. Use a piece of cardboard
or paper to search for leaks. Do not use
hand.
Fluid injected into skin must be
surgically removed within a few hours
by a doctor familiar with this type of
injury or gangrene will result.
WARNING
Electrocution Hazard
Death or injury can result from contacting electric
power lines.
Always contact the electric power line owner. The
electric power shall be disconnected or the power lines
moved or insulated before machine operations begin.
1263140 A
DANGER
Maintain required clearance.
Line Voltage Required Clearance
0 to 300V Avoid Contact
300V to 50KV 10 ft 3.05 m
50KV to 200KV 15 ft 4.60 m
200KV to 350KV 20 ft 6.10 m
350KV to 500KV 25 ft 7.62 m
500KV to 750KV 35 ft 10.67 m
750KV to 1000KV 45 ft 13.72 m
over 1000 KV
see operator manual