Type "PXXX" Faults
DTC
Number
Message on
GCON LCD
Problem
Description
Possible
Causes
Failure
Mode
P001
P001:PWR FAULT
SW PWR1:Bat-
Short circuit of the switched
power #1 circuit to battery
negative.
• Short circuit in switched power #1, down limit
switch, pothole limit switch, digital tilt switch
harness.
• GCON ECM.
All functions
inhibited.
P003
P003:PWR FAULT
SW PWR1:Bat+
Short circuit of the switched
power #1 circuit to battery
positive.
• Short circuit in switched power #1, down limit
switch, pothole limit switch, digital tilt switch
harness.
• GCON ECM.
All functions
inhibited.
P004
P004:DEVICEFAULT
HORN:Bat-
Short circuit of the automotive
horn circuit to battery negative.
• Short circuit in automotive horn harness.
• Automotive horn short circuit.
• GCON ECM.
Automotive horn
inhibited.
P005
P005:DEVICEFAULT
HORN:Open
Open circuit of the automotive
horn circuit.
• Open circuit in automotive horn harness.
• Automotive horn open circuit.
• GCON ECM.
Automotive horn
inhibited.
P006
P006:DEVICEFAULT
HORN:Bat+
Short circuit of the automotive
horn circuit to battery positive.
• Short circuit in automotive horn harness.
• Automotive horn short circuit.
• GCON ECM.
Automotive horn
inhibited.
P007
P007:DEVICEFAULT
GCON ALARM:Bat-
Short circuit of the GCON
alarm circuit to battery
negative.
• Short circuit in GCON alarm harness.
• GCON alarm short circuit.
• GCON ECM.
GCON alarm
inhibited.
P009
P009:DEVICEFAULT
GCON ALARM:Bat+
Short circuit of the GCON
alarm circuit to battery positive.
• Short circuit in GCON alarm harness.
• GCON alarm short circuit.
• GCON ECM.
GCON alarm
inhibited.
P013
P013:PWR FAULT
PCON PWRET:Bat-
Short circuit of the PCON
power return circuit to battery
negative.
• Short circuit in PCON power return harness.
• GCON ECM.
All functions
inhibited.
P015
P015:PWR FAULT
PCON PWRET:Bat+
Short circuit of the PCON
power return circuit to battery
positive.
• Short circuit in PCON power return harness.
• GCON ECM.
All functions
inhibited.
P018
P018:PWR FAULT
PCON POWER:Bat-
Short circuit of the PCON
power circuit to battery
negative.
• Short circuit in PCON power harness.
• GCON ECM.
All functions
inhibited.
P019
P019:PWR FAULT
PCON POWER:Bat+
Short circuit of the PCON
power circuit to battery
positive.
• Short circuit in PCON power harness.
• GCON ECM.
All functions
inhibited.