Service and Repair Manual
September 2016
Ground Controls
62
GS-84 • GS-90
Part No. 1272222
10 Use the yellow platform down arrow to scroll to
motion alarm.
Result: MOTION ALARM is showing in the
diagnostic display window.
11 Press the lift function enable button to activate
or deactivate the motion alarm option OR use
the yellow platform down arrow to scroll to
motion beacon.
Result: MOTION BEACON is showing in the
diagnostic display window.
12 Press the lift function enable button to activate
or deactivate the motion beacon option.
Note: For this option to function correctly, the
machine must be equipped with flashing beacons.
13 Use the yellow platform down arrow to scroll to
overload.
Result: OVERLOAD ON is showing in the
diagnostic display window.
Result: OVERLOAD OFF is showing in the
diagnostic display window. Press the lift
function enable button to activate the overload
option.
Note: For CE models, the overload option should
be activated or in the on position.
14 Use the yellow platform down arrow to scroll to
sim operation.
Result: SIM OPERATION OFF is showing in
the diagnostic display window.
Result: SIM OPERATION ON is showing in
the diagnostic display window. Press the lift
function enable button to deactivate the sim
operation option.
Note: For AS and CE models, the sim operation
option should be deactivated or in the off position.
15 Use the yellow platform down arrow to scroll to
beacons option.
Result: BEACONS OFF is showing in the
diagnostic display window. Press the lift
function enable button to activate or
deactivate the beacons option.
Note: For this option to function, the machine must
be equipped with flashing beacons.
16 Use the yellow platform down arrow to scroll to
generator option.
Result: GENERATOR OFF is showing in the
diagnostic display window. Press the lift
function enable button to activate or
deactivate the generator option.
Note: For this option to function correctly, the
machine must be equipped with the required
generator components.
17 Use the yellow platform down arrow to scroll to
outriggers option.
Result: OUTRIGGERS OFF is showing in the
diagnostic display window. Press the lift
function enable button to activate or
deactivate the outrigger option.
Note: For this option to function correctly, the
machine must be equipped with the required
outrigger components.
CE models with all software revisions:
18 Use the yellow platform down arrow to scroll to
return to the main menu.
Result: RETURN TO MAIN MENU is showing
in the diagnostic display window.
19 Press the lift function enable button.
Result: SELECT OPTIONS is showing in the
diagnostic display window.
20 Push in the red Emergency Stop button to the
off position at the ground controls.
Summary of Contents for GS-3384
Page 170: ...Service and Repair Manual September 2016 158 Deutz D 2 9 L4 Engine Wire Harness ...
Page 180: ...Service and Repair Manual September 2016 168 Electrical Schematic Ford Engine Models ANSI CSA ...
Page 188: ...Service and Repair Manual September 2016 176 Electrical Schematic Ford Engine Models AS CE ...
Page 189: ...September 2016 Service and Repair Manual 177 Electrical Schematic Deutz Engine Models AS CE ...
Page 193: ......