Service and Repair Manual
September 2016
Deutz D 2.9 L4 Engine Fault Codes
126
GS-84 • GS-90
Part No. 1272222
SPN = Suspect Parameter Number
FMI = Failure Mode Identifier
KWP = Keyword Protocol
SPN FMI
KWP
Description
654
3
583
Injector 4 (in firing order); short
circuit
654
4
589
High side to low side short circuit
in the injector 4 (in firing order)
654
5
571
Injector 4 (in firing order);
interruption of electric connection
676
11
543
Cold start aid relay error.
676
11
544
Cold start aid relay open load
677
3
956
Starter relay high side; short
circuit to battery
677
3
960
Starter relay low side; short
circuit to battery
677
4
957
Starter relay high side; short
circuit to ground
677
4
961
Starter relay low side; short
circuit to ground
677
5
958
Starter relay; no load error
677
12
959
Starter relay; powerstage over
temperature
703
3
426
Engine running lamp; short circuit
to battery
703
4
427
Engine running lamp; short circuit
to ground
703
5
424
Engine running lamp; open load
703
12
425
Engine running lamp;
powerstage over temperature
729
5
545
Cold start aid relay open load
729
12
547
Cold start aid relay; over
temperature error
898
9
305
Timeout Error of
CAN-Receive-Frame TSC1TE;
Setpoint
1079 13
946
Sensor supply voltage monitor
1 error (ECU)
1080 13
947
Sensor supply voltage monitor
2 error (ECU)
SPN FMI
KWP
Description
1109 2
121
Engine shut off demand ignored
1136 0
1398
Physikal range check high for
ECU temperature
1136 1
1399
Physikal range check low for
ECU temperature
1136 3
1400
Sensor error ECU temperature;
signal range check high
1136 4
1401
Sensor error ECU temperature;
signal range check low
1176 3
849
Sensor error pressure sensor
upstream turbine; signal range
check high
1176 4
850
Sensor error pressure sensor
downstream turbine; signal range
check high
1180 0
1193
Physical range check high for
exhaust gas temperature
upstream turbine
1180 0
1460
Turbocharger Wastegate CAN
feedback; warning threshold
exceeded
1180 0
1462
Exhaust gas temperature
upstream turbine; warning
threshold exceeded
1180 1
1194
Physical range check low for
exhaust gas temperature
upstream turbine
1180 1
1461
Turbocharger Wastegate CAN
feedback; shut off threshold
exceeded
1180 1
1463
Exhaust gas temperature
upstream turbine; shut off
threshold exceeded
1180 3
1067
Sensor error exhaust gas
temperature upstream turbine;
signal range check high
1180 11
1066
Sensor exhaust gas temperature
upstream turbine; plausibility
error
1188 2
1414
Wastegate; status message from
ECU missing
Summary of Contents for GS-3384
Page 170: ...Service and Repair Manual September 2016 158 Deutz D 2 9 L4 Engine Wire Harness ...
Page 180: ...Service and Repair Manual September 2016 168 Electrical Schematic Ford Engine Models ANSI CSA ...
Page 188: ...Service and Repair Manual September 2016 176 Electrical Schematic Ford Engine Models AS CE ...
Page 189: ...September 2016 Service and Repair Manual 177 Electrical Schematic Deutz Engine Models AS CE ...
Page 193: ......