Speed Dome Camera Instruction Manual
18/49
Video
Use BNC coaxial cable only.
Alarm Input
Sensor Input is detected by Short or Open between Sensor IN Terminal and COMMON
Terminal.
If you want to use Alarm Input, the types of sensors must be selected. The sensor types
are divided into Normal Open and Normal Close. If wrong sensor types are selected,
alarms should be activated reversely to sensor inputs.
Normal Open A sensor activates when a Sensor IN Terminal and COMMON
Terminal are Short
Normal Close A sensor activates when a Sensor IN Terminal and COMMON
Terminal are Open
Relay Output
The maximum loads are as follows.
Power Type
DC Power
Maximum Load
MAX. DC 12V, 2.5A
INSTALLATION