7. Adjustment
Caution!
When used in conjunction with the flow regulator on the HOD output (
red
) no
external flow regulation is necessary.
Water temperature at the HOD outlet should be in the range of 40 to 50 degrees
centigrade (but may vary in some situations).
7. Switch on the HOD unit at the main socket.
8. Undo the access cover on the GS and press and hold button “B” for 10 seconds. This
will open the water solenoid for 5 minutes and allow water to enter the LL tank. This in
course will then be pumped up to the main tank .Repeat as necessary to fill the Main
Tank of the GS.
9. Check the water temperature entering the main tank. It should be warm to the touch.
10. When water flows over the outlet weir of the main tank outlet the unit is charged and
ready for use.
11. Replace the end Cover.