background image

 

2.1.2 Single DVR 

C

onfigurat

io

n

 

 

RS-485(-) PIN No.5

RS-485(+) PIN No.4

POWER

AC 24V

AC 24V

POWER

POWER

AC 24V

BNC

MULTIPLEXER

SPOT MONITOR

MAIN MONITOR

BNC

BNC

AWG # 24

SW1

T

XB(

T

X-

)

TX

A

(TX

+

)

RX

A

RX

B

TX

A

TX

B

TX

B

TX

A

RX

B

RX

A

1 AUX OUTPUT

4 ALARM INPUT

RS-485 or
RS-422 HALF  DUPLEX  MODE

TX

A

(TX

+

)

R

XB(

R

X

 -

)

R

XA(

R

X

+)

T

XB(

T

X-

)

FGND AC- AC+

TXB TXA RXB RXA

RX

A

RX

B

TX

A

AC+

AC

-

TX

B

VIDEO

Tx

+(

DOME

1

+

)

T

x

-(

D

O

M

E

1

 -)

4 ALARM INPUT

RS-422
FULL DUPLEX  MODE

1 AUX OUTPUT

J4 ALARM2

1

COM  B

2

NC B

3

NO  B

4

GND

5

ALARM8

6

ALARM7

7

ALARM6

8

ALARM5

J2 ALARM1

1

COM  A

2

NC A

3

NO  A

4

GND

5

ALARM4

6

ALARM3

7

ALARM2

8

ALARM1

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Figure 3 – Single DVR

 

 

Summary of Contents for KB-1000/JS

Page 1: ...JOYSTICK CONTROLLER Please read this manual thoroughly before use and keep it handy for future reference Version 2 0 07 2010 Instruction Manual KB 1000 JS ...

Page 2: ... with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated dangerous voltage within the product s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance servicing in...

Page 3: ...ENCE TO RADIO COMMUNICATIONS OPERATION OF THIS EQUIPMENT IN A RESIDENTIAL AREA IS LIKELY TO CAUSE HARMFUL INTERFERENCE IN WHICH CASE THE USER WILL BE REQUIRED TO CORRECT THE INTERFERENCE AT HIS OWN EXPENSE CAUTION CHANGES OR MODIFICATIONS NOT EXPRESSLY APPROVED BY THE PARTY RESPONSIBLE FOR COMPLIANCE COULD VOID THE USER S AUTHORITY TO OPERATE THE EQUIPMENT THIS CLASS A DIGITAL APPARATUS COMPLIES W...

Page 4: ...t an electrician for replacement of the obsolete outlet 10 Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where it exits from the apparatus 11 Only use attachments accessories specified by the manufacturer 12 Unplug this apparatus during lightning storms or when unused for long periods of time 13 Refer all servicing to qualified s...

Page 5: ...ing Chapter 2 0 INSTALLATION 2 1 Connection Diagram 2 2 Dip Switch Setting 2 3 Basic Operation 2 4 Configuring the Controller 2 5 Operating the Controller Chapter 3 0 KEY Description 3 3 1 Key Description of the Controller DVR 3 3 2 Keys for DVR Appendix A SPECIFICATION ...

Page 6: ...iate camera call ups of preset position views with automatic zoom and focus Program 8 patterns which comprise a sequential series of pan tilt zoom and focus movements from a single camera One define continuous rotation with 16 scans 8 tours consisting of 64 of the presets patterns scan and tour is expandable to over 400 functions with nested tours Global preset recalls the preset of all dome camer...

Page 7: ...equipment and make sure all listed items are included in the box Contents of Joystick Controller box Joystick Controller 1 Junction Box optional 3m Cable optional M4 Self Tapping Screws optional Instruction Manual 1 12VDC SMPS 1 ...

Page 8: ...1 TXA DOME1 STP AWG 22 VIDEO BNC MONITOR AC 24V POWER TXB AC AC FGND TXA RXB RXA AC 24V POWER TXB TXA RXB RXA FGND AC AC TXB TX RXA RX RXB RX TXA TX RS 422 HALF DUPLEX MODE RS 485 or 4 ALARM INPUT 1 AUX OUTPUT RXA RXB TXA TXB TXB TXA RXB RXA TXA TX TXB TX SW1 Figure 1 Basic Installation Diagram Figure 2 Basic Installation Diagram with J Box ...

Page 9: ...TXB TXA RXB RXA 1 AUX OUTPUT 4 ALARM INPUT RS 485 or RS 422 HALF DUPLEX MODE TXA TX RXB RX RXA RX TXB TX FGND AC AC TXB TXA RXB RXA RXA RXB TXA AC AC TXB VIDEO Tx DOME1 Tx DOME1 4 ALARM INPUT RS 422 FULL DUPLEX MODE 1 AUX OUTPUT J4 ALARM2 1 COM B 2 NC B 3 NO B 4 GND 5 ALARM8 6 ALARM7 7 ALARM6 8 ALARM5 J2 ALARM1 1 COM A 2 NC A 3 NO A 4 GND 5 ALARM4 6 ALARM3 7 ALARM2 8 ALARM1 Figure 3 Single DVR ...

Page 10: ...R 1ST MULTIPLEXER Spot 1 Mux2 Cam 16 RS 485 PIN No 5 RS 485 PIN No 4 POWER AC 24V AC 24V POWER POWER AC 24V BNC AWG 24 SW1 1 AUX OUTPUT 4 ALARM INPUT FGND AC AC TXB TXA RXB RXA RXA RXB TXA AC AC TXB VIDEO Tx DOME1 Tx DOME1 4 ALARM INPUT 1 AUX OUTPUT Camera 1 16 Spot 2 Mux2 Cam 15 Spot 4 Mux2 Cam 13 Spot3 Mux2 Cam 14 Camera 17 12 15 Figure 4 Two DVR ...

Page 11: ...ER Spot 1 Mux2 Cam 16 RS 485 PIN No 5 RS 485 PIN No 4 POWER AC 24V AC 24V POWER POWER AC 24V BNC AWG 24 SW1 1 AUX OUTPUT 4 ALARM INPUT FGND AC AC TXB TXA RXB RXA RXA RXB TXA AC AC TXB VIDEO Tx DOME1 Tx DOME1 4 ALARM INPUT 1 AUX OUTPUT Camera 1 16 Spot 2 Mux2 Cam 15 Spot 4 Mux2 Cam 13 Spot3 Mux2 Cam 14 Camera 17 12 15 Figure 5 Two DVR with Slave Controller ...

Page 12: ...gth for communication should not exceed 1 2Km Refer to Figure 7 for setting the dome camera and keyboard controller termination TERMINATION ON TERMINATION ON TERMINATION ON TERMINATION ON TERMINATION ON TERMINATION ON TERMINATION ON TERMINATION ON TERMINATION ON TERMINATION ON TERMINATION ON TERMINATION ON TERMINATION ON TERMINATION ON TERMINATION ON TERMINATION ON TERMINATION ON TERMINATION ON TE...

Page 13: ...CONTROLLER SYS V x x Password _ Unless the password has been changed 9999 Enter is the default administrator s password and 1111 for user If you forget your own password contact your distributor The joystick controller displays the following screen and is ready to control the dome camera 9 9 9 9 Press and then consecutively 9999 Enter SYS Press key to get back to system mode from DVR control mode ...

Page 14: ...y causes the DVR mode to be cycled F F SYS Press key to go back to system mode from DVR control mode 2 4 Configuring the Controller If a user needs to setup the network passwords or perform special tasks such as uploading and downloading programmed data from the dome cameras hold down the key and then press key Shft Menu The following menu is displayed Joystick Up Down scrolls menu items push the ...

Page 15: ... 4 digit current user s password New Password Enter new 4 digit password Confirm Password Confirm new 4 digit password Note Factory default Administrator s password is 9999 Enter and User password is 1111 Enter If you forget your own password contact your distributor Save and Exit Save the programmed data and return to the previous Menu exit without save if the key is pressed ESC PORT Shft Menu ÎP...

Page 16: ... Device to be controlled Controller None Baud Rate Communication speed 2400 4800 9600 19200 38400 57600 11 5K 230K Save and Exit Press key to exit without saving the data ESC DVR SETUP MENU Shft Menu ÎPORT SETUP MENUÎDVR DVR SETUP MENU Device DVR Alarm AUX IN IO None Baud Rate 9600 2400 230K Save and Exit Device Select Device to be controlled DVR Alarm AUX IN AUX IO None Baud Rate Communication sp...

Page 17: ...le RVT S S2e P D Push the stick to right and set the baud rate by twisting zoom handle Select whether receive alarm from the dome or not Alarm OFF simplex Alarm ON half duplex Press OFF key to delete the dome ID ENTER key to save exit Press ESC key to exit without saving Time Date Shft Menu ÎTime Date TIME DATE Setup Display ON OFF Date Format Asia US EURO 2005 JAN 18 Time Format 12 24 08 59 04 Da...

Page 18: ...sstick scrolls to the previous next page on the first last row Twist the zoom handle on the camera ID field to enter program mode and select ID Rotating the handle causes the programmed IDs programmed in camera setup menu to be scrolled Push the joystick to the right to setup alarm field Activate or deactivate specific alarm inputs by rotating the zoom handle And then program the remaining parts A...

Page 19: ...ached on the control line It is same effect as sending 999 888 888 Global Night shot off 999 Global Data Select Bank Shft Menu V V V Î Data SELECT DATA BANK ID Saved Date Data Bank Exit Slave Controller Setup Shft Menu V V V Î Slave Controller Setup Slave Controller Setup No of Controller 0 1 8 DVR Control Enable Disable Camera Menu Access Enable Disable Clear saved Data Exit No of Controller 0 1 ...

Page 20: ...R must be selected before being controlled by the joystick controller Press Numeric button then button to change DVR ID to be controlled ex 1 Select DVR ID 3 Press numeric then button on the controller DVR 003 is displayed on the LCD window DVR 3 DVR ex 2 Select DVR ID 73 Press and then button DVR 073 is displayed on the LCD window DVR 3 7 2 5 2 How to Control On Screen Menu Press Function Key to ...

Page 21: ...21 1 The first time that Function Key is pressed a Search menu is displayed as below Note External Search menu is used for Mpeg DVR 2 Second page 3 3rd page ...

Page 22: ...22 2 5 3 Joystick 1 Menu Control 2 Pan Tilt Zoom Control 1 2 Press SYS button to use Preset or Tour ...

Page 23: ... first then select Preset No ex Preset No3 Move the camera to your desired area and then press No3 Shift Preset PRESET SHIFT b Go to To move preset position press Number then Preset ex Preset No3 Press No3 then press Preset button ...

Page 24: ...lbl Normal mode Call Preset position Pressing Prst brings up the preset programming menu Recalls preset e g 1 2 31 240 Prst In the preset or tour programming mode the operator can review the existing preset selected by cursor by pressing this key Tour Pressing Tour brings up the tour programming menu directly Recalls programmed presets or functions sequentially e g 1 8 Tour Pattern Pressing Ptrn b...

Page 25: ...R Play Pause Play recorded data Pause playing Rewind Play video backward at high speed Pressing the button again toggles the playback speed from and Fast Forward Play video forward at high speed Pressing the button again toggles the playback speed from and Stop Preset Save During Playback mode returns the DVR to the Live Monitoring mode Record Preset Call Set the DVR so that it is ready to record ...

Page 26: ...on Weight Communication 12VDC 0 5A RS 485 RS 232C 2400 230K bps 0 C to 50 C 32o F to 140o F 0 to 90 RH non condensing 20 C to 60 C 40o F to 122o F Professional Joystick 390x190x65 Professional Joystick 1 2kg Dome Connection Max 64 simplex 256 DVR Connection Max 100 Design and Product specifications subject to change without notice ...

Reviews: