Linking

Use 3-pin XLR data cables to link the controller to DMX lighting 
equipment.

3-pin XLR connectors are follows:

Building a serial DMX-chain:

Connect the DMX output of the first fixture with the DMX input of the 
next fixture. And execute all the setups following the above-
mentioned instruction.
Flip the DIP SWITCH #3 of last fixture to  ON  position for terminal 
confirmation.

1

2

3

1

2

3

1:Ground 
2:Signal(-) 
3.)

1:Ground 
2:Signal(-) 
3.)

DMX-output 

XLR mounting-socket:

DMX-input 

XLR mounting-plug:

7

Connection with the mains

Connect the device to the mains with the power-plug.

The occupation of the connection-cables is as follows:

Cable 

Pin 

International 

Brown 

Live 

Blue 

Neutral 

Yellow/Green 

Earth 

 

 

The earth has to be connected! In general, lighting effects should not
 be connected to dimming-packs.

Summary of Contents for MOVING HEAD OBY-3

Page 1: ...TM MOVING HEAD OBY 3 User manual CAUTION...

Page 2: ...nimating stages If any question or suggestion you have please offer the precious recommendation for improving our products and designs better and create perspective and expectancy about future lightin...

Page 3: ...tch ON OFF Stylish high impact resistant polymer shell which is lighter than any one else of the same class in the market Solid square base is convenient set on the TRUSS or directly stand on the grou...

Page 4: ...Description of the appearance 2...

Page 5: ...damage or loss caused by transportation Contact your Geni dealer to assure your right by telephone or facsimile immediately if damage has occurred or if something is missing Packing List A OBY 3 Movi...

Page 6: ...o qualified technicians only Lamp and components become hot during operation Allow time to cool before handling Keep flammable material at least one meter away from unit Do not operate in wet conditio...

Page 7: ...p in the lampholder securely and then put back B and A for the complete installation Remove the power cord and set the unit as to the figure Loosen the screws with appropriate tools and extract A See...

Page 8: ...arious venues Mount two attached brackets a on the bottom See Figure and collocate the appropriate clamps b to rig with trusses Must use the safety ropes that can hold the ten times as heavy as the fi...

Page 9: ...he DIP SWITCH 3 of last fixture to ON position for terminal confirmation 1 2 3 1 2 3 1 Ground 2 Signal 3 Signal 1 Ground 2 Signal 3 Signal DMX output XLR mounting socket DMX input XLR mounting plug 7...

Page 10: ...ing the spring ring into the fixture Rotating GOBO wheel 4 Insert the new GOBO and the spring ring Press the spring ring tight with the appropriate tools in order to keep GOBO compact screw up the top...

Page 11: ...st max 7 flashes second Channel 2 Shutter Strobe Open white Steel Blue Orange Green Blue Bright Blue Bright Pink Red Deep Blue Yellow Dark Pink Moss Green Light Blue Color wheel rotation slow to fast...

Page 12: ...fast 127 191 255 0 128 192 4 Channel 6 Prism wheel Open position Triple prism static Triple prism forwards rotation from fast to slow Triple prism backwards rotation from slow to fast Triple prism st...

Page 13: ...be fine tuned from zero to 2 2 degrees 10 Channel 11 Tilt fine tune While rotating vertically the head is allowed to be fine tuned from zero to 1 degree 11 Channel 12 Reset Normal state 127 0 Mechani...

Page 14: ...12 Function of the control channels 8 bit protocol DMX Channel Function 1 DIMMER 2 SHUT 3 COLOR 4 GOBO 5 GOBO ROTATE 6 PRISM AND ROTATE 7 FOCUS 8 PAN COARSE 9 TILT COARSE 10 AUTO RESET 11 LAMP ON OFF...

Page 15: ...Control Board 13...

Page 16: ...ast half yearly using a vacuum cleaner or an air jet Caution Be careful not to damage the interior mechanical structures or circuits when using the air jet To ensure a proper function and smooth rotat...

Page 17: ...on before replacing the fuse Replace the fuse as follows Step 1 Unscrew the screw of the fuse holder on the housing counterclockwise with appropriate tools Step 2 Remove the broken fuse and then repla...

Page 18: ...Product Specifications 16 120V 8A 230V 5A 350VA...