![GENI MOVING HEAD OBY-3 User Manual Download Page 8](http://html1.mh-extra.com/html/geni/moving-head-oby-3/moving-head-oby-3_user-manual_2211712008.webp)
a
a
d
Oby-3 can be set on the flat stage floor directly or use clamp to mount on
any kinds of trusses for fitting the mobility of various venues.
Mount two attached brackets(a) on the bottom (See Figure ), and
collocate the appropriate clamps(b) to rig with trusses. Must use the
safety ropes that can hold the ten times as heavy as the fixture through
the eye bolts(c) on the bottom of the base and trusses; then join the
safety ropes with screw-on carabines(d).
Rigging:
6