GENI IRDW-7024156-00D-11 User Manual Download Page 3

 

Remarks: 
X is the number from 0 to 9. 
XX is the number from 00 to 10. 
XXX is the temperature of the LED board. 
III.Slave Mode: 
1.

DMX mode & Address setting

: 

Hold the button “

MENU”

 until the mode is changed to the DMX mode, loose you finger, the working 

mode will be changed to the DMX mode automatically. Also you can change the DMX address to press 

UP” or 

DOWN” Button

. If you hold the button of “

UP” or 

DOWN”

, then the DMX address will be 

changed rapidly. The address range is from 001 to 512.

 

 
2.

DMX mode function chart:

: 

CH1 

CH2 

CH3 

CH4 

CH5 

CH6~CH26 

0~40 Black Out 

NA 

NA 

NA 

NA 

NA 

41~80 Dimmer 

Flash

All Red  All Green

All Blue 

NA 

81~120 Dimmer 

Flash

Red 1 

Green 1 

Blue 1 

Red2,Green2,Blue2~Red8,Green8,Blue8

121~160Color 

Flash 

Flash

Color 

NA 

NA 

NA 

201~240Color 

Speed

NA 

NA 

NA 

NA 

0~29 

Programe 

30~59 

Programe 

60~89 

Programe 

90~119 

Programe 

120~149 

Programe 

150~179 

Programe 

180~209 

Programe 

241~255 Dream 

Flow 

Speed

Fade 

210~255 

Programe 

NA 

NA 

3.

DMX connector pin

: 

Male & Female DMX connector pin: Pin1 = Gnd    Pin2 = Dmx-      Pin3 = Dmx+

   

4,

DMX Linking Method

: 

                                                                                                                                                                  Page 3 of 5 