background image

Product Features and Applications

 

Primary Applications 

Recommended for commercial and residential softening or demineralization water treatment systems.

Softening System Pre-Treatment

Iron Removal System

Ion Exchange Equipment

Boiler Softening Water Treatment

RO Pre-Treatment

Product Characteristics

• Mechanical 

     

Components

The Genesis 2 AIO used internal ceramic discs which are corrosion and abrasion resistant to form and hermetic

 

seal. Rotation of the upper disc aligns to the corresponding lower disc ports for Service, Backwash, Brine & Slow

 

Brine, Brine Refill and Fast Rinse modes.

• Excellent

      

 Flow 

      

Rate: 

Up to 20 gpm @ 15 psi drop

• 365 

 

       

Day 

        

Usage 

            

Memory

• Manual / Delayed 

R

egeneration

Pressing       at any time results in an immediate manual regeneration.
Pressing and holding       for 3 seconds, when system is locked, results in a delayed regeneration at the

 

preselected time.

• Extended 

       

Power 

           

Outage

      

 Indicator

If outage exceeds 3 days, the time of day indicator "

     

  " will flash 12:12. The current time of day needs to be

 

re-set.

 All other set parameters remain stored in memory. The valve will resume to operate  form the point of 

the

 

power outage.

T

hree 

   

Regeneration 

   

Sequences

• Lockout Function

Keypad will lock after 5 minutes without use. To access the parameter changes press and hold   and 
simultaneously for 3 seconds to unlock.

• LCD Display Screen
• Maximum Day Regeneration Interval

When the valve reaches the maximum programmed service days, without reaching the set service capacity, it
will trigger a regeneration at the pre-programmed time of day. Regeneration(s) reset both the maximum day
regeneration value and the service capacity value.

• One Button to Change the Current Time
   Pressing and holding the   button for 3 seconds, when system is locked, allows the current time of day to be 
   adjusted.
• Service Alarm

When the service alarm feature counts-down and reaches set point, (Selectable 30 day min to 900 day max in
30 day increments) the alarm will activate at 8pm. The alarm will sound for 2 minutes and then shut off
automatically. To silence alarm within the 2 minute period, press any button. A service call message will then
appear on the screen as a signal for the homeowner to contact a water treatment professional for routine
service. To eliminate this message from the screen, unlock the valve programming by pressing the UP and
DOWN arrows simultaneously until the padlock in the upper left corner of the screen disappears
(approximately 3 seconds). Next, enter the programming menu by pressing the MENU/CONFIRM button once
and then pressing the BACK/REGENERATION button once. The system will then go back to normal status and
the operational days will re-start new count-down. Note: The system will operate normally when it is displaying
the service alarm message.

4

Summary of Contents for GEN2AI015

Page 1: ...GENESIS 2 OZONE FILTRATION SYSTEM SERVICE MANUAL J J z l 1 w z s REVISION 1 REVISION DATE 9 17 2020 support www discount watersofteners com...

Page 2: ...lication Check List and Flushing Instructions 2 System Specifications 3 Product Features and Applications 4 Product Dimensions and Specification 5 Pre installation Checklist 6 Installation 7 8 Program...

Page 3: ...n and suspended solids 7 The start up backwash and rinse prior to new service installation is critical for cleaning media of manufacturing color taste and any trace amine odors We recommend 2 bed volu...

Page 4: ...tions GEN2AIO25 GEN2AIO30 72 2 74 150 90 72 1 91 200 120 14 16 15 20 3 4 20 120 PSI 1 to 5 PPM Ferrous Control Valve Working Conditions Transformer Input Transformer Output Water Pressure Water Tempur...

Page 5: ...ously for 3 seconds to unlock LCD Display Screen Maximum Day Regeneration Interval When the valve reaches the maximum programmed service days without reaching the set service capacity it will trigger...

Page 6: ...reaches zero A 03 Intelligent Meter Delay The same delay function as A 01 but the capacity is determined by entering the total Resin Capacity Feed Water Hardness and the Number of People in the househ...

Page 7: ...m Any modifications the Discount Water Softeners equipment which is outside the standard scope of supply voids the product warranty Discount Water Softeners equipment like all modern electronic device...

Page 8: ...ipment installed in inappropriate applications or environment are not covered by warranty Plumbing and Mechanical Setup Note 1 If making a soldered copper installation all sweat soldering should be do...

Page 9: ...Installation Continued Ceramic Bypasses Part Number 41205 Ceramic Bypass 8...

Page 10: ...e basic programming mode modify highlighted options and return to the main menu Manual Regen Esc Key Press at any phase during manual regeneration to advance to the next phase or press during programm...

Page 11: ...cts reported to Discount Water Softeners Inc outside of the warranty period This warranty does not apply to defects caused by installing operating servicing modifying repairing or maintaining or lack...

Reviews: