The operating principle of the humidifier is based on the most efficient and economical means of evaporating 
water to the air.  The humidifier uses only 2.5 watts of electrical power during operation; the heat necessary 
for evaporating water is produced by the furnace.  

• 

The water supply to the humidifier is controlled by the electric solenoid valve.  The humidistat connected in 
series with the solenoid provides low voltage control of the humidifier.  The humidistat is designed for wall 
mounting in the living area or surface mounting on the return air duct.  

• 

CAUTION

:  

Do not set relative humidity too high during cold weather.  

Excessive humidity may cause condensation on windows or in walls.  
Refer to recommended settings as described in the humidistat owners 
manual. 

• 

Water flows through a strainer, is metered through an orifice to provide 
the proper amount of water, and is supplied to the evaporator pad by 
the distributor trough.  Approximately 200 CFM of air is by-passed 
from the warm air plenum through the humidifier and returned to the 
cold air plenum.  Moisture is evaporated to the air passing through the 
evaporator pad. Minerals are not blown into the air stream as occurs in 
atomizing humidifiers; they are left on the evaporator pad where a high 
percentage is carried off with the waste water.

• 

When the humidifier is installed and operating, no adjustments are 
necessary other than setting the control knob on the humidistat to the desired level of humidification.  Leave 
knob on the humidifier pointing towards the "WINTER" position. To turn the humidifier off, close water supply 
valve, switch electrical power off and turn humidistat off.  If furnace is used for summer cooling or ventilating 
set air damper to the "SUMMER" position.

How The Humidifier Works

At Outside 

Temperature

Recommended 

Setting

-20°F

-29°C

15%

-10°F

-23°C

20%

0°F

-18°F

25%

+10°F -12°C

30%

+20°F

-7°C

35%

+30°F

-1°C

40%

!

Maintenance

Your humidifier is engineered to give helpful and trouble-free humidification.  For maximum efficiency the 
following cleaning procedures should be carried out at the end of each heating season:
     

1.  Turn off the water supply and electrical power to the humidifier.
2.  Remove water cover, distributor trough, evaporator pad and drain pan. Clean excessive mineral deposits 

from the distributor trough,  drain pan, pad rails, and humidifier cabinet.  A solution of 1/2 vinegar & 1/2 
water will help loosen mineral deposits.

3.  Replace humidifier evaporator pad if necessary (P/N GA570).  Install trough and drain pan.                    

Replace cover.  Replace evaporator pad yearly for peak performance.  

4.  In heavy mineral areas or if the solenoid valve fails to function disconnect the 1/4” water supply line from the 

solenoid valve.  Carefully pull the strainer screen (P/N GA4004)  from the  valve body  (P/N 900-6).  Clean 
the mineral deposits from all parts.  If the orifice is clogged, it may be opened by inserting a small pin.  
Reinsert the filter into the orifice fitting and screw the brass strainer body into the solenoid valve.

5.  Reconnect the 1/4” water line to the solenoid valve if necessary.  Turn on the water supply and check 

all points for leakage.  The operation of the unit may be checked by starting the furnace.  The humidifier 
operates only when the furnace blower is running or the burner circuit is energized.  The humidifier is now 
ready for operation.

6.  During the summer, turn OFF the water supply and electrical power to the humidifier.  Close air damper.

Summary of Contents for 5705

Page 1: ...anty Modification or alteration of product parts installation instructions or local safety codes voids warranty Read our full warranty policy at the end of this document Please Read And Save These Instructions Canadian General Filters Ltd 400 Midwest Rd Toronto ON M1P3A9 Canada Toll Free 888 216 9184 www cgfproducts com General Filters Inc 43800 Grand River Avenue Novi Michigan 48375 Toll Free 866...

Page 2: ...he Control 6 How The Humidifier Works 7 Maintenance 7 Parts Drawing 8 Inside Your Box 8 Humidifier Chassis Cut Out 9 Trouble Shooting 9 FAQ s 10 Limited Warranty 11 12 Model 570 Table of Contents WARNING This symbol indicates IMPORTANT INSTRUCTIONS Failure to heed them can result in serious injury or death CAUTION This symbol indicates IMPORTANT INSTRUCTIONS Failure to heed them can result in seri...

Page 3: ...Installation Warm Air Return Air Plenum Right or Left Side Plenum Opening Inches 8 7 8 W x 9 1 2 H Bypass Opening Inches 6 Pallet Qty 36 Cabinet Construction UV Stable Automotive Grade Plastic Humidistat Included M Models MHX3C A Models GFX3 Voltage 24VAC In The Box Humidifier Humidistat Control Bypass Damper 24V Transformer Solenoid Valve Vapor Pad Saddle Valve GCV3412 Code Valve A Models Install...

Page 4: ...de of humidifier on cabinet centerline using connecting collar as guide The bypass is reversible and can be mounted on the right or left side of the humidifier 2 The humidifier is self retaining Slide the top side in first then slide the chassis down Level the chassis and install center screws If the by pass pipe installs to opposite side of chassis bend clip on chassis remove side panel and reins...

Page 5: ...her a cold or a hot water pipe A side or top mount is best to avoid clogging from pipe sediment Connect 1 4 O D tubing to the saddle valve Copper tubing requires a brass compression nut and brass sleeve Plastic tubing requires a brass insert inside the tubing a plastic sleeve on the outside with a brass compression nut CAUTION Do not use plastic tubing on hot water or in contact with any hot plenu...

Page 6: ...OOR TEMP SENSOR N W 24v 60CY ACC EAC HOT C 115v 60CY ON OFF SWITCH COMMON LEAD FURNACE C HI LO GA50 CURRENT SENSING RELAY MULTI SPEED BLOWER MOTOR 24V SOLENOID VALVE HUMIDISTAT 24 V TRANSFORMER HOT C 115v 60CY ON OFF SWITCH 24V SOLENOID VALVE 24V SOLENOID VALVE 24 V TRANSFORMER L1 C NO HOT L2 115v 60CY ON OFF SWITCH 12500 AIR PRESSURE SWITCH 24 V TRANSFORMER HUM FURNACE CONTROL BOARD C 24v 60CY 24...

Page 7: ...se water supply valve switch electrical power off and turn humidistat off If furnace is used for summer cooling or ventilating set air damper to the SUMMER position How The Humidifier Works At Outside Temperature Recommended Setting 20 F 29 C 15 10 F 23 C 20 0 F 18 F 25 10 F 12 C 30 20 F 7 C 35 30 F 1 C 40 Maintenance Your humidifier is engineered to give helpful and trouble free humidification Fo...

Page 8: ...Solenoid Assembly Integral Bypass Damper Accessories MHX3C Manual Humidistat 24V Transformer Saddle Valve Parts Drawing 900 14 DRAIN PAN 900 11 DAMPER KNOB 900 28 DAMPER DISK 570 2 SIDE PANEL DISCHARGE 570 40 PAD RAIL GA 10 EVAPORATOR PAD 900 15 DISTRIBUTOR TROUGH 570 13 COVER GA4231 YELLOW ORIFICE P190 COMP SLEEVE PLASTIC P102 COMP SLEEVE BRASS P101 COMPRESSION NUT 570 1 CHASSIS 900 9 NOZZLE 900 ...

Page 9: ... be caused by any of the following Verify water supply is on Verify metering orifice is not obstructed Very hard water with high mineral content may restrict the metering orifice in as little as one heating season Replace Yellow metering orifice GA4231 if restricted GFI 7580 3 The humidifier runs without furnace operation or humidifier never shuts off Check for the following Verify humidifier and ...

Page 10: ...ater flow If you subject the pad to cleaning you usually remove much of the coating and the pad becomes ineffective This reduces the output of the humidifier and increases water consumption Replace the Vapor Pad annually 5 Why would I want to install a humidifier For many reasons 1 Since the air in your home is always trying to reach its saturation point it will absorb water wherever it can from t...

Page 11: ...ervicing or replacing parts is not covered under this Limited Warranty What is Not Covered Cont Shipping charges are not covered by this Limited Warranty Agreements made by third parties that are not listed in this Limited Warranty Liability for special incidental direct indirect collateral and consequential damages is excluded Some states do not allow limitation of incidental damages so the limit...

Page 12: ...manufacturer will in no event be liable for incidental or consequential damages This limited warranty gives you specific legal rights and you may also have other rights which vary from state to state Some states do not allow either limitations on implied warranties or exclusions from incidental or consequential damages so the above exclusion and limitation may not apply to you Questions Any questi...

Page 13: ...pression REMARQUE NE PAS UTILISER DE TUYAUX EN PLASTIQUE AVEC DE L EAU CHAUDE OU SUR UNE SURFACE DE CONTACT CHAUDE DE PLÉNUM OU DE CONDUIT L INSTALLATION DE CE ROBINET VANNE À ÉTRIER DOIT RESPECTER OU DÉPASSER LES EXIGENCES DES CODES LOCAUX ET AUTRES ORDONNANCES 4 2 1 2 DÉBIT D AIR VERS LE HAUT RETOUR D AIR AIR CHAUD DRAIN 15 2 cm 6 po 24 1 cm 9 1 2 po 22 5 cm 8 7 8 po Le modèle 570 de peut être i...

Page 14: ...V 60 Hz COMMUTATEUR DE MARCHE ARRÊT 12500 PRESSOSTAT D AIR TRANSFORMATEUR DE 24 V HUM C 24 V 60 Hz VANNE ÉLECTROMAGNÉTIQUE DE 24 V HUMIDISTAT HUMIDISTAT HUMIDISTAT 7E 7G 7F 7H 7A à 7D Humidistat électronique 7A Vers la carte de circuits imprimés de l appareil de chauffage de 24 volts 7B Vers la source d alimentation constante utilisant un transformateur de 24 V et un manostat 7C Vers la carte de c...

Page 15: ...nt lorsque le ventilateur de l appareil de chauffage est en marche ou que le circuit du brûleur est activé L humidificateur est maintenant prêt à fonctionner 6 Pendant la période estivale fermer l alimentation en eau et en électricité de l humidificateur Fermer le registre à air SOIN ET ENTRETIEN GARANTIE LIMITÉE Cet humidificateur lorsqu il est enregistré correctement en retournant la carte d enr...

Page 16: ... pi2 164 m2 1770 pi2 279 m2 3000 pi2 34 9 cm 13 3 4 po 39 4 cm 15 1 2 po 33 6 cm 13 1 4 po CARACTÉRISTIQUES DE L HUMIDIFICATEUR ELITE 570 Performance d humidité prévue selon la superficie en mètres carrés pieds carrés et le type de construction ACCESSOIRES DES COMPOSANTS DE L HUMIDIFICATEUR EMBALLÉ Critères de base de la performance de l humidificateur 34 1 cm 9 1 2 po 22 5 cm 8 7 8 po ÉTÉ HIVER G...

Reviews: