General AOH12RSJC Operating Manual Download Page 7

Все каталоги и инструкции здесь:

 http

:

//splitoff.ru/tehn-doc.html

En-6

To Stop Operation

Press the START/STOP button.

The OPERATION indicator lamp (red) (Fig. 3 

5

) will go out.

About AUTO CHANGEOVER Operation

AUTO:

When AUTO CHANGEOVER operation first selected, the fan will oper-
ate at very low speed for about one minute, during which time the unit
detects the room conditions and selects the proper operating mode.

If the differance between thermostat setting and actual room tempera-
ture is more than +2 °C 

 Cooling or dry operation

If the difference between thermostat setting and actual room tempera-
ture is within ±2 °C 

 Monitor operation

If the difference between thermostat setting and actual room tempera-
ture is more than –2 °C 

 Heating operation

When the air conditioner has adjusted your room’s temperature to near
the thermostat setting, it will begin monitor operation. In the monitor
operation mode, the fan will operate at low speed. If the room tem-
perature  subsequently  changes,  the  air  conditioner  will  once  again
select the appropriate operation (Heating, Cooling) to adjust the tem-
perature to the value set in the thermostat.

(The monitor operation range is ±2 °C relative to the thermostat set-
ting.)

If the mode automatically selected by the unit is not what you wish,
select one of the mode operation (HEAT, COOL, DRY, FAN).

About Mode Operation

Heating:

Use to warm your room.

When Heating mode is selected, the air conditioner will operate at very
low fan speed for about 3 to 5 minutes, after which it will switch to the
selected fan setting. This period of time is provided to allow the indoor
unit to warm up before begin full operation.

When the room temperature is very low, frost may form on the outside
unit,  and  its  performance  may  be  reduced.  In  order  to  remove  such
frost, the unit will automatically enter the defrost cycle from time to
time. During Automatic Defrosting operation, the OPERATION indica-
tor lamp (red) will flash, and the heat operation will be interrupted.

Cooling:

Use to cool your room.

Dry:

Use for gently cooling while dehumidifying your room.

You cannot heat the room during Dry mode.

During Dry mode, the unit will operate at low speed; in order to adjust
room humidity, the indoor unit’s fan may stop from time to time. Also,
the fan may operate at very low speed when adjusting room humidity.

The fan speed cannot be changed manually when Dry mode has been
selected.

Fan:

Use to circulate the air throughout your room.

During Heating mode:

Set the thermostat to a temperature set-
ting that is higher than the current room
temperature. The Heating mode will not
operate if the thermostat is set lower than
the actual room temperature.

During Cooling/Dry mode:

Set the thermostat to a temperature set-
ting that is lower than the current room
temperature. The Cooling and Dry modes
will  not  operate  if  the  thermostat  is  set
higher than the actual room temperature
(in Cooling mode, the fan alone will oper-
ate).

During Fan mode:

You can not use the unit to heat and cool
your room.

9312175024-01_en.pm6.5

2004.2.5, 8:58 AM

6

Summary of Contents for AOH12RSJC

Page 1: ...här nedan Os seguintes produtos referenciados na lista abaixo estão em conformidade com as normas Соответствуя указанным стандартам данные изделия отвечают требованиям ниже перечисленных директив a EC Council Directive 73 23 EEC b EC Council Directive 89 336 EEC Place of Issue F R Germany Title of Authority General Manager Date of Issue 1 NOVEMBER 2002 Declaration Reference FUJITSU GENERAL EURO Gm...

Page 2: ...NIDAD EXTERIOR Altura anchura profundidad 535 650 250 mm Peso 26 kg NETO PRESSIONE MASSIMA ASPIRAZIONE 800 kPa EMISSIONE 2 700 kPa REFRIGERANTE R22 650 g DIMENSIONI E PESO APPARECCHIO INTERNO Altezza Larghezza Profondità 257 808 187 mm Peso 8 0 kg netti APPARECCHIO ESTERNO Altezza Larghezza Profondità 535 650 250 mm Peso 26 kg netti ΜΕΓΙΣΤΗ ΠΙΕΣΗ ΑΝΑΡΡΟΦΗΣΗ 800 kPa ΕΚΤΟΝΩΣΗ 2 700 kPa ΨΥΚΤΙΚΟ R22 6...

Page 3: ...llows convenient con trol of air conditioner operation SWING OPERATION The Air Flow Direction Louvers swings automatically up and down so that the air speeds to every nook and corner of your room REMOVABLE INTAKE GRILLE The indoor unit s Intake Grille can be removed for easy clean ing and maintenance MILDEW RESISTANT FILTER The AIR FILTER has been treated to resist mildew growth thus allowing clea...

Page 4: ...EL TIMER button R FAN CONTROL button S START STOP button T AIR FLOW DIRECTION button U SWING LOUVER button V ACL button W TEST RUN button This button is used when installing the conditioner and should not be used un der normal conditions as it will cause the air conditioner s thermostat function to op erate incorrectly If this button is pressed during normal op eration the unit will switch to test...

Page 5: ... If the remote control unit s operating range becomes appre ciably reduced replace the batteries and press the ACL button with the tip of a ballpoint pen or other small object Turn on the Power 1 Connect the Power Supply Plug Fig 1 C to an electri cal outlet in the case of a direct line connection turn on the circuit breaker Load Batteries R03 LR03 2 1 Press and slide the battery compartment lid o...

Page 6: ...al room temperature To Set the Fan Speed Press the FAN CONTROL button Fig 6 R Each time the button is pressed the fan speed changes in the following order AUTO HIGH MED LOW QUIET About three seconds later the entire display will reappear When set to AUTO Heating Fan operates so as to optimally circulate warmed air However the fan will operate at very low speed when the temperature of the air issue...

Page 7: ...ditioner will operate at very low fan speed for about 3 to 5 minutes after which it will switch to the selected fan setting This period of time is provided to allow the indoor unit to warm up before begin full operation When the room temperature is very low frost may form on the outside unit and its performance may be reduced In order to remove such frost the unit will automatically enter the defr...

Page 8: ...rder Set the time while the ON TIMER mark on the remote control unit s display is flashing The flashing will continue for about 30 seconds 3 Press SET button Fig 6 P to select ON TIMER opera tion The ON Timer mark will be shown on the remote control unit s dis play The Indoor Unit Timer Indicator Lamp green Will light It can not be used during OFF TIMER operation To Cancel the Timer Press the CANC...

Page 9: ...ically modifies the thermostat set ting in accordance with the time setting When the time has elapsed the air conditioner completely stops During Cooling Dry operation When the SLEEP timer is set the thermostat setting is auto matically raised 1 C every sixty minutes When the ther mostat has been raised a total of 2 C the thermostat set ting at that time is maintained until the set time has elapse...

Page 10: ... Direction Louvers are left in the heat ing range for more than 30 minutes they will automatically return to posi tion 3 When used in a room with infants chil dren elderly or sick persons the air direction and room temperature should be considered carefully when making settings Vertical Air Direction Adjustment Press the AIR FLOW DIRECTION button Fig 6 T Each time the button is pressed the air dir...

Page 11: ...west downward range for more than 30 minutes the unit will automatically switch the swing range to the horizontal flow range to prevent the condensation of moisture on the outlet MANUAL AUTO OPERATION Use the MANUAL AUTO operation in the event the Remote Control Unit is lost or otherwise unavailable How To Use the Main Unit Controls Press the MANUAL AUTO button Fig 2 2 on the main unit control pan...

Page 12: ...erly to their holes in the panel 2 Close the Intake Grille For purposes of example the illustration shows the unit without Intake Grille installed Dust can be cleaned from the Air Filter either with a vacuum cleaner or by washing the filter in a solution of mild detergent and warm water If you wash the filter be sure to allow it to dry thoroughly in a shady place before reinstalling If dirt is all...

Page 13: ...air conditioner resulting in condensation and misting During Heating operation the outdoor unit s fan may stop and steam may be seen rising from the unit This is due to Automatic Defrosting operation When Heating operation is started fan speed is temporarily very low to allow internal parts to warm up During Heating operation if the room temperature rises above the thermostat setting the outdoor u...

Page 14: ...the OPERATION indicator lamp red will flash Heating Performance This air conditioner operates on the heat pump princi ple absorbing heat from outdoor air and transferring that heat indoors As a result the operating performance is reduced as outdoor air temperature drops If you feel that insufficient heating performance is being produced we recommend you use this air conditioner in conjunction with...

Page 15: ...may operate to prevent internal circuit damage Also during Cooling and Dry modes if the unit is used under conditions of lower temperature than those listed above the heat exchanger may freeze leading to water leakage and other damage Do not use this unit for any purposes other than the Cooling Dehumidifying and air circulation of rooms in ordinary dwellings If the unit is used for long periods un...