AF500 AIR-SCRUB-R
®
Portable HEPA Air Filter
FORM GOM24101701US, VERSION 1.0
English-EN
9
FIGURE 11
STOPPING AIR-SCRUB-R
12. Turn AIR-SCRUB-R ON/OFF switch to OFF position between each use
or when moving from one major section of work area to another. Refer to
FIGURE 7
13. Disconnect power cord from power source.
14. BEFORE removing machine from work area, clean per STEP 6 of
MAINTENANCE INSTRUCTIONS in this manual. All other equipment
used in conjunction with the AIR-SCRUB-R should be considered
contaminated and cleaned per specific machine instructions.
8 MAINTENANCE INSTRUCTIONS
For routine maintenance, the following information should be followed at
minimum once per week or 40 hours of use for maximum performance and
return on investment unless otherwise indicated. Information is for reference
only and is not intended to be all inclusive.
1.
Use factory approved replacement parts/accessories only for
maintenance and repair.
2.
All maintenance/repairs not described in this operator manual must be
done by a dedicated service center following a specific service/repair
manual.
3.
STOP AIR-SCRUB-R BEFORE performing maintenance and service per
STOPPING AIR-SCRUB-R in OPERATING INSTRUCTIONS section of
this manual.
4.
Remove accessory couplers and ducting per INSTALLING & REMOVING
PRIMARY & ACCESSORY DUCTING in MACHINE SET-UP section of
this manual.
5.
Inspect for loose, broken, cracked or deformed parts. Inspect all
fasteners, individual parts, operator controls and safety devices for proper
function. Tighten fasteners as necessary. Replace any worn or damaged
part or assembly.
6.
Remove all loose material accumulations, dirt and grease on
internal/external surfaces, impeller blade, inlet and outlet to prevent
safety hazards, poor performance and reduced service life. Use certified
HEPA dust collection system as necessary to remove most accumulation
then use damp cloth with mild soap and water or vinyl cleaner/protectant
or safety type solvent for final AIR-SCRUB-R cleaning. Dry thoroughly
BEFORE operating.
7.
Inspect AIR-SCRUB-R ON/OFF switch for proper function. If damaged or
worn, replace.
8.
Inspect carry handle grip is free of moisture, pitch, oil or grease and is not
cracked or damaged. If full of dirt or pitch, clean. If cracked or damaged,
replace unit.
9. Inspect all safety and operation decals for proper condition. If any decal
becomes damaged and/or unreadable, replace.
10. Inspect primary ducting for dirt/and oil build up on inside and outside
surfaces. Clean as necessary with mild soap and water for improved air
flow/performance. Repair holes/tears. If unrepairable, replace.
REPLACING PRE-FILTER & HEPA SECONDARY FILTER
Tools Required:
1 each, Phillips-tip screw driver
1 each, airflow meter or anemometer
NOTE:
One or both filters may require replacement. Decision to replace a filter
should be based on cost versus filtering effectiveness. Based on job site
application, operator must determine if airflow below 500 CFM is acceptable
(e.g. - 250 CFM will filter particulates from space at half the rate, but will still
filter the air).
WARNING
•
Operating AIR-SCRUB-R utilizing components not
meeting minimum operational standards can result in
property damage and/or personal injury.
DANGER
•
Use safety type solvent.
•
DO NOT use thinner, benzene, or other volatile solvents
that will attack rubber/plastic components when cleaning
AIR-SCRUB-R.
•
Provide adequate ventilation.
•
DO NOT smoke while using cleaning solvents.
•
DO NOT use solvents with motor running or if it is hot.
•
Allow ample time for motor to cool BEFORE using
solvents.
•
An ignition source in close proximity to hot motor can be
the source of an explosion, resulting in property damage
and/or personal injury.
WARNING
•
Replace both filters after each mold remediation or other
application where hazardous materials/contaminants are
present and being filtered such as crystalline silica dust,
asbestos, or lead.
•
Clean unit thoroughly (per IICRC S520, 10.11) after each
job before removing from containment area to prevent
cross contamination/spread of hazardous matter.
•
DO NOT use pressure wash or high pressure air to clean.
•
Dispose of filters, cleaning materials and post service
parts per international and local regulations.
•
Not following these procedures can result in personal
injury to maintenance personnel and future operators of
unit.
DANGER
•
Wear safety eyewear and other safety apparel appropriate
for the job application and/or job site environment.
•
Improper safety procedures can result in property
damage and/or personal injury.
WARNING
•
Stop AIR-SCRUB-R when moving from one major section
of work area to another.
•
DO NOT choose to save time (time required to restart
machine), money (if AIR-SCRUB-R is being rented) or gain
added convenience by electing to keep machine running
between major sections.
•
Never leave AIR-SCRUB-R running and unattended.
•
Not doing so can result in property damage and/or
personal injury.