9.
Use the second belt clamp to attach the collector
bag to the lower portion of the drum,
Q
.
Note: Before tightening the clamp make sure the metal
strap is sitting in the groove on the lower portion of the
drum,
R
, to create an airtight seal between the drum and
the bag.
Q
R
10.
Fit the canister cleaning handle onto the top of the
canister, then tighten the screw against the flat end
of the shaft as shown.
OPERATING INSTRUCTIONS
ALWAYS TURN ON THE DUST COLLECTOR BEFORE STARTING YOUR DUST PRODUCING MACHINE AND ALWAYS STOP THE
DUST PRODUCING MACHINE BEFORE TURNING OFF THE DUST COLLECTOR.
BEFORE STARTING
1.
To minimize airborne dust make sure that all hoses, fittings and clamps are secure and airtight.
2.
For maximum system efficiency, make sure a cover is installed on any unused hose inlet openings.
3.
Never operate the machine without the filter bag or canister and the collection bag properly installed.
THE SOUND LEVEL OF THIS MACHINE IS RATED AT APPROXIMATELY 80-85 DB DURING OPERATION. MAKE SURE THAT ADEQUATE
HEARING PROTECTION IS USED AND THAT THE OVERALL SOUND LEVEL WITHIN THE WORKING ENVIRONMENT IS TAKEN INTO
CONSIDERATION.
BASIC INSTRUCTIONS
This Model 10-030CF M1 Dust Collector has been designed to capture, remove, and collect non-metallic dust and
wood dust around the workshop and from woodworking machinery.
ON/OFF SWITCH
The model 10-030CF M1 is equipped with a simple “rocker
style” On/Off switch featuring a removable lock out safety
key.
To prevent unauthorized use or unintentional start-up,
remove the safety key and store it in a safe place when-
ever the dust collector is not in use.
To start the dust collector, insert the safety key and pull up
the switch. To stop the machine, push down on the power
switch.
POWER ON
POWER OFF
SAFETY KEY
(PREVENTS START-UP
WHEN REMOVED)
MAKE SURE THE SWITCH IS IN THE “OFF” POSITION BEFORE PLUGGING IN THE POWER CORD.
REMOVE THE SWITCH KEY WHENEVER THE DUST COLLECTOR IS NOT IN USE. PLACE IT IN A SAFE PLACE AND OUT OF THE
REACH OF CHILDREN.
11