background image

Jet-Set JM-1000™  

SPECIAL APPLICATIONS 

ICE BLOCKAGES 

High pressure water can be used to clear an ice blockage. A 3000 psi 
gas jet can clear a 4” line at an approximate rate of one foot per min-
ute. The smaller, electric jet will take twice as long. Ambient air tem-
perature will effect these times. Use a 15° nozzle with a forward jet. 
DO NOT allow the incoming water supply to exceed 90°F (32°C) or it 
could  cause  damage  to  the  pump.  Remember  to  follow  the  cold 
weather precautions found in the Freeze Protection section. 
 

FREEZE PROTECTION 

To protect your machine from severe damage caused by water freez-
ing inside the components, it is important to winterize it whenever it is 
subjected to freezing temperatures. 
The best way to protect the system is to keep it out of the cold. Bar-
ring that, the next best way is to flush the system with anti-freeze. To 
do so, simply attach a short garden hose (not to exceed four feet) to 
inlet  on  the  jet  and  put  other  end  into  the  anti-freeze  container.  Be 
sure  to  remove  the  nozzle  from  the  hose.  Turn  the  machine  on  to 

draw  anti-freeze  into  the  system.  When  anti-freeze  flows  out  of  the 
end  of  the  hose,  turn  the  machine  off.  When  preparing  to  operate 
equipment for the next job, remove the anti-freeze. To do so, recon-

nect water source, turn jet on and direct flow of anti-freeze back into 
container.  Be  careful  not  to  dilute  anti-freeze  with  incoming  water 
supply. Anti-freeze, if kept relatively undiluted, can be used again and 
again. 
Hoses can also be protected from freezing by using compressed air to 
clear  them  of  residual  water.  Remember  to  remove  the  nozzle  from 
the jet hose. 

SHUT DOWN INSTRUCTIONS 

After  drain  cleaning  or  spray  washing  is  completed,  run  clear  water 
through the system. Turn off  water supply and drain  as much  water 
from the pump as possible. Remove water supply hose from inlet. If 
you are in a cold climate, see Freeze Protection section. 

PULSE

 

Pulsation makes the hose vibrate, helping the jet go longer  distances 
and around tight bends easier. Pulse  causes  the  water  to  burst  from 
the nozzle  hundreds  of  times  per second. Pulse  is  most  effective  in 
the 1/8” hose.  

1.  Select  the  correct  jet  hose  size  to  match  the  line  size  you  are 

clearing.  (See Hose Guide) Check all hoses for wear and dam-
age. Tighten all connections securely. Note: If you are using a new 
jet hose, run water through it to flush out debris before connecting 
a nozzle. 

2.  Select the correct nozzle and attach to the end of the hose. (See 

Nozzle Selection Guide)  Clean nozzles before and after each use. 

3.  Insert the jet hose 2 to 3 feet into the drain line before turning on 

machine.  

4.  Turn on the water supply valve fully to allow for maximum flow.   
5.  Turn ON shut-off valve at the end of the supply hose. 
6.  Allow  water to run through the supply hose, through the jet, and 

out of the jet hose to purge air from system before turning on the 
machine. 

7.  Plug in GFCI power cord to proper receptacle and voltage. 
8.  While  holding  onto  hose  firmly  to  prevent  hose  from  whipping 

around, turn the jet power switch on. 

9.  Guide the jet hose into the drain line. Do not feed the hose con-

tinuously, but rather, move the hose forward and back to allow the 
pressure to break up the  stoppage and the water flow to flush it 
away. If you are clearing the line from the upstream side, this may 
take more time. Clearing the line from the downstream side allows 
debris to flow away easily. 

10. The  JM-1000  includes  full  time  Pulse.  The  vibration  generated 

helps  to  hose  overcome  the  friction  in  the  line  and  glide  farther 
down the line. See Pulse section. 

11. When  the  jet  hose  encounters  a  bend,  it’s  advance  will  usually 

slow or stop. The hose has a slight bend in it from the hose reel. It 
may be necessary to manually feed or rotate the jet hose to work it 
around  the  bends.  If  the  hose  won’t  advance,  put  the  hose  in  a 
loop and rotate it a quarter to half turn so the curve of the hose 
matches the pipe. It may also be necessary to pull the hose back 
six  inches  and  snap  it  forward  to  hop  across  a  gap  in  the  pipe 
fitting.  

12. Once  you  reach  the  stoppage,  pass  the  hose  back  and  forth 

through the section several times to ensure the line is thoroughly 
cleared.  You  may  also  switch  nozzles  to  a  wide  spray  or  rotary 
(optional) nozzle for wall to wall cleaning action.    

OPERATION 

NEVER POINT THE END OF THE JET HOSE AT A 

PERSON WHILE OPERATING. 

 

MAINTENANCE

 

Regular inspection is the key to preventing breakdowns and prolong-
ing the life of the equipment. Follow this simple procedure religiously. 

DAILY 

 

Check INLET STRAINER for debris before each use. 

 

Check that the jet nozzles are not clogged or worn out. 

 

Clean nozzles between each use. 

 
WEEKLY 

 

Check  the  pressure  hose  for  wear  and  damage.  Damaged  hose 

can  be  repaired  at  a  local  service  dealer,  or  by  your  equipment 
dealer. 

DISCONNECT JETTER FROM POWER SOURCE     

BEFORE PERFORMING MAINTENANCE OR MAKING 

ANY ADJUSTMENTS. 

Summary of Contents for Mini-Jet JM-1000-A

Page 1: ...rs of trouble free profitable service However no ma chine is better than its operator Read understand and follow all safety warnings and instructions provided with the product Failure to follow the warnings and instructions may result in electric shock and or serious injury Save all warn ings and instructions for future reference SAVE THESE INSTRUCTIONS ...

Page 2: ... ignite causing prop erty damage or severe injury Always wear safety glasses and rub ber soled non slip shoes High pres sure spray can cause paint chips or other particles to become airborne and fly at high speeds Use of this safety equipment may prevent serious injury These instructions are intended to familiarize all personnel with the safe operation and maintenance procedures for the JM 1000 DA...

Page 3: ... wet hands Reduces the risk of electric shock GROUND FAULT CIRCUIT INTERRUPTER GFCI Your machine is equipped with a ground fault circuit interrupter which protects you against shock if a short circuit should occur Check that receptacle is properly grounded Test the GFCI before each use 1 Plug into 120 volt receptacle 2 Push test button Indicator light will go out and power to machine should cut of...

Page 4: ...ose Some nozzles may have an orifice in the front to cut through the stoppage All will have holes in the back to drive the hose down the line and clean the walls of the pipe A tight spray pattern 15 has more driving power for long runs a wide spray pattern 30 does a better job of cutting the grease off of the walls of the pipe A combination of nozzles may be required to clear a line Always turn of...

Page 5: ...being used to clear ice blockages see instructions on Ice Blockages 6 When using a new hose run water through it to clean it out before attaching the nozzle NOZZLE SELECTION GUIDE HOSE SIZE 1 8 CAT 15 Rear Jets w No Forward Jet JN 1 15 Rear Jets w One Forward Jet JN 2 30 Rear Jets w No Forward Jet JN 3 Spring Leader JNSL 1 Down Head Nozzle Optional JNDH 1 Rotary Nozzle Optional JN RA 2 JN RB 2 Rot...

Page 6: ...ater through it to flush out debris before connecting a nozzle 2 Select the correct nozzle and attach to the end of the hose See Nozzle Selection Guide Clean nozzles before and after each use 3 Insert the jet hose 2 to 3 feet into the drain line before turning on machine 4 Turn on the water supply valve fully to allow for maximum flow 5 Turn ON shut off valve at the end of the supply hose 6 Allow ...

Page 7: ... plumbing or air leak in inlet plumbing Repair clogged inlet fittings Check supply hose and ensure adequate water supply Damaged pump Replace any damaged pump parts and clean out any foreign particles Clogged nozzle Clean or replace nozzle Water leakage at intake Worn pump Repair or replace pump Inadequate water supply to pump creating a vacuum lock Ensure adequate tap water supply Clear inlet fil...

Page 8: ...Jet Set JM 1000 General Wire Spring Co 1101 Thompson Avenue McKees Rocks PA 15136 412 771 6300 www drainbrain com General Wire Spring Co 2018 C JM 1000OI 1218 ...