Document #: GP-UM-POS-002-21
Page 28 of 30
Scheme 3: Low frequency RF detection. The low frequency correlation noise between
two polarization channels is an indication of the channel crosstalk. The noise will be
minimized when the two polarization channels are properly separated. A low frequency
photodetector followed by a bandpass filter can be used to detect the noise level. A
simple circuit can be used to convert the noise level into a 0.5 to 4.6V feedback signal for
the POS-002-E: the bigger the noise, the smaller the feedback signal. The polarization
tracker then automatically maximizes the feedback signal to effectively separate the two
polarization channels.
Scheme 4: Power imbalance detection. The two polarization channels are set at different
power levels and the detected power difference is an indication of polarization channel
separation. A simple circuit can be used to convert the noise channel power difference
into a 0.5 to 4.6V feedback signal for the POS-002-E. The polarization tracker then
automatically maximizes the feedback signal to effectively separate the two polarization
channels.
TX1
TX2
RX1
RX2
PBC
//
//
TX1
TX2
Pol. Mux
RX1
RX2
PBC
PBS
Bandpass
filter for low
freq. RF signal
Pol. DeMux
Polarization
Monitor
PBC
PBS
//
//
TX2
RX1
RX2
TX1
Polarization
Monitor
PD2
PD1
V1-V2
//
BS
BS
Pol. DeMUX
Pol. MUX
G2
G1
苏州波弗光电科技有限公司
苏州波弗光电科技有限公司
苏州波弗光电科技有限公司
苏州波弗光电科技有限公司
苏州波弗光电科技有限公司
苏州波弗光电科技有限公司
苏州波弗光电科技有限公司
苏州波弗光电科技有限公司
苏州波弗光电科技有限公司
苏州波弗光电科技有限公司
苏州波弗光电科技有限公司
苏州波弗光电科技有限公司
苏州波弗光电科技有限公司
苏州波弗光电科技有限公司
苏州波弗光电科技有限公司
苏州波弗光电科技有限公司
苏州波弗光电科技有限公司
苏州波弗光电科技有限公司
苏州波弗光电科技有限公司
苏州波弗光电科技有限公司
苏州波弗光电科技有限公司
苏州波弗光电科技有限公司
苏州波弗光电科技有限公司
苏州波弗光电科技有限公司
苏州波弗光电科技有限公司
苏州波弗光电科技有限公司
苏州波弗光电科技有限公司
网址:www.bonphot.com
电话:0512-62828421