GM8802C-DWeighing Transmitter
74 GM8802C-D110101
5.4.4.8 Reading Register 1-9
Sending Command format:
STX
Scale ID
R
Parameter code
CRC
CR
LF
Received data sequence is correct:
STX
Scale ID
R
Parameter code
DDDDDD
CRC
CR
LF
Received data sequence is incorrect:
STX
Scale ID
R
Parameter code
N
O
CRC
CR
LF
Here:
Parameter code
——
2bits, R1—R9
,
refer to parameter address of registers to write-in
parameter codes, for example, write-in register
F3.3, then the parameter code is R3
(
52H
33H
)
For example:
Command from upper computer
:
02 30 31 52 52 31 31 32 0D 0A
(reading register
F3.1
)
Correct response format
:
02 30 31 52 52 31 30 30 30 35 30 30 30 35 0D 0A
Incorrect response format
:
02 30 31 52 52 31 4E 4F 36 39 0D 0A