background image

FUNCTIONS

Temperature Control

The  room  thermostat  controls  the  room  temperature  according  to  the  set  value.  The  on  /  off  temperature 

o

difference of the device is 0.5 C.

Calibration

The room thermostat can be calibrated if the measuring temperature wanted to be changed. The calibration range 

o

o

is -8 C to + 8 C.

ORDERING

When ordering, specify both the product type and the product code, for example the HT270 SET wireless room 

thermostat.

ROOM THERMOSTAT INSTALLATION

Remove the room thermostat by pulling it out of the wall bracket. If you want to use your room thermostat in a fixed 

place, mount the dismantled wall apparatus in a room you frequently use in your living space. If you want to use 

your room thermostat with the table bracket, place the room thermostat on the table bracket by removing the wall 

bracket. For example; Like your home lounge or living room. Avoid installing the room thermostat where there is a 

lot of air circulation, such as door entry or window edge. Also, do not place near heating units (heating panels, 

fireplaces etc.) and direct sunlight areas. We recommend that the room thermostat is placed at a height of 50 cm 

to 150 cm from the floor. You can try a few places to find where you can place the room thermostat.

If the room thermostat is to be used with the wall bracket, the wall bracket must be mounted on a flat wall.

Local electrical regulations must be observed during installation.

Installation of room thermostat must be done by authorized personnel.

The parts included in the room thermostat are made of ABS, PC materials.

In systems with room thermostats, if there are thermostatic radiator valves, keep them in the open position.

BATTERY CHANGE

Remove the battery cover located on the back of your room thermostat. Insert a 3V DC (2xAAA) alkaline battery 

into the battery compartment. When installing batteries, make sure they are incorrect position. Place the room 

thermostat in the wall bracket or table bracket by closing the battery cover. Replace both batteries at the same 

time.

WARNING!

Please dispose of your discharged batteries in waste bin which is separated for battery wastes.

MAINTENANCE

The device is maintenance-free.

generallife.com.tr

4 / 11

50 cm-150 cm

min.50 cm

Summary of Contents for HT270 SET

Page 1: ...HERMOSTAT generallife com tr HT270 SET v 1 0 Product Code Data sheet V No HT270 SET Wireless Room Thermostat Large LCD Backlight Display Daily and Weekly Program Touch Keys Key Lock Battery Indicator...

Page 2: ...tery USAGEAREAS Houses Apartments Residences Schools O ces The device can be used on combi boilers and on all on off heating systems operating at 220V AC 7A current and voltagevalues MECHANICALDESIGN...

Page 3: ...ife room temperature and heating symbol are displayed The heating o symbol gives information about the operation status of the boiler The product measures 0 1 C temperature o accuracy However there is...

Page 4: ...try or window edge Also do not place near heating units heating panels replaces etc and direct sunlight areas We recommend that the room thermostat is placed at a height of 50 cm to150cmfromthe oor Yo...

Page 5: ...ler s user manual Input receiver power cable rst to receiver than to plug If there is no plug near your boiler you can connect cable toyourboiler sconnectionfuse After nishing connections turnonelectr...

Page 6: ...ON APPLICATIONEXAMPLE generallife com tr Actuator Type of Actuator Operating Voltage ST21 SEA21 10 Thermal Motor AC 230 V AC 230 V 2 Position 2 Position 180 sn 20 sn Positioning Type Positioning Time...

Page 7: ...ibration menu press one more time to On Off button and Adr menu which is a synchronizationmenuwillshowup In Adr menu when either one of the temperature adjustment button pressed thermostat will send s...

Page 8: ...sed for 3 seconds Set degree of that speci c mode would appear on the screen and by pressing Temperature Adjustment Buttons degree can be reset After nishing setting the degree same Mode buttonneedsto...

Page 9: ...9 3 V2 1 1 2017 EN 300 220 2 V3 1 1 2017 EN 62479 2010 EN 60730 2 9 2010 EN 60730 1 2011 2014 30 EU EMC EN 61000 6 3 2007 A1 2011 EN 61000 6 1 2007 2014 35 EU LVD EN 60730 2 9 2010 EN 60730 1 2011 Gen...

Page 10: ...DIMENSIONS generallife com tr 10 11 118 mm 80 mm 6 mm 85 mm 28 5 mm 90 mm 119 5 mm 24 mm 85 mm 80 mm 60 mm 21 mm O C C O C...

Page 11: ...ISIPARK reserves the right to change and develop the product speci cations and data sheet For all changes please visit generallife com tr...